 | Choke - 0.17 - 250, Heavy Duty Hash Choke Molded powdered iron core. 1-1/4 long axial leads. High inductance & high current. L measured at 1 Khz. Inductance: 250 µH20% tolerance DC resistance ohms: .17 Self Resonant Frequency (MHz): 1.5 Maximum DC current amps: 2.5 Coil diameter (in): .43 Core Length (in): 1.25 | $1.75 More Details |
 | Transformer - IF, 455 KC Red Cap, Detector 455 kHZ | $0.50 More Details |
 | Transformer - Hammond, Filament, 5 VCT, 3 A Primary 115 VAC, 60 Hz. Center tapped secondary. Enclosed, 4 hole chassis mount. Minimum 6 long leads. Dual bobbin design - no electrostatic shield required. Class B insulation (130 degreesC) Hi-Pot test of 2000 V RMS. UL listed (# E50394) & CSA certified (# LR3902). Specifications Rating: 5 VCT3 A Weight: 1.1 lbs Mounting Centers: 1.5" x 1.31"vertical | $26.60 More Details |
 | Transformer - Hammond, Filament, 6.3 VCT, 10 A Primary 115 VAC, 60 Hz. Center tapped secondary. Open style, channel bracket, two hole chassis mount. Minimum 6 long leads. Dual bobbin design - no electrostatic shield required. Class B insulation (130 degreesC) Hi-Pot test of 2000 V RMS. UL listed (# E50394) & CSA certified (# LR3902). Specifications Rating: 6.3 VCT10 A Mounting Centers: 3.56"u-bracket Weight:2.2 lbs | $36.30 More Details |
 | Transformer - Hammond, Power, 400-0-400 V, 465 mA Universal Primary - 100, 110, 120, 200, 220, 240 VAC 50/60 Hz. High voltage secondary designed for full wave center tapped use. 50 VAC bias tap from high voltage secondary C.T. Black epoxy painted to match our P-T1650 series of output transformers . Class A insulation (105 degrees C). Hi-Pot test of 2,000 V RMS. Windings are concentric wound for low stray field and low noise Secondary: 400-0-400 V, 465 mA Filament winding : 6.3 VCT, 6 A Mounting centers: 3.5 x 4" vertical mount Weight: 17.6 lbs. | $173.66 More Details |
 | Transformer - Hammond, Power, 190-0-190 V, 65 mA Universal Primary - 100, 110, 120, 200, 220, 240 VAC 50/60 Hz. High voltage secondary designed for full wave center tapped use. 50 VAC bias tap from high voltage secondary C.T. Weight 2.6 lbs Black epoxy painted to match our P-T1650 series of output transformers . Class A insulation (105 degrees C). Hi-Pot test of 2,000 V RMS. Windings are concentric wound for low stray field and low noise Secondary: 190-0-190 V, 65 mA Filament winding: 6.3 VCT, 2.5 A Mounting centers: 2 x 1.69" vertical mount | $64.70 More Details |
 | Transformer - Hammond, Power, 400-0-400 V, 250 mA Designed specifically for 300B's Universal Primary - 100, 110, 120, 200, 220, 240 VAC 50/60 Hz. High voltage secondary designed for full wave center tapped use. 50 VAC bias tap from high voltage secondary C.T. Black epoxy painted to match our P-T1650 series of output transformers . Class A insulation (105 degrees C). Hi-Pot test of 2,000 V RMS. Windings are concentric wound for low stray field and low noise Secondary: 400-0-400 V, 250 mA Filament winding 1 : 5 VCT, 1.2 A Filament winding 2 : 5 VCT, 3 A Filament winding 3 : 6.3 VCT, 6 A Mounting centers: 3 x 3.81" vertical mount | $170.24 More Details |
 | Transformer - Hammond, Power, 360-0-360 V, 120 mA Dual primary 115 VAC, 125 VAC, 60 Hz. Secondary DC current measured with cap. input filter, full wave (two diode) C.T., rectifier circuit. Enclosed, 4 hole chassis mount. Minimum 6 long leads. Class A insulation (105 degrees C). Hi-Pot test of 2000 V RMS. Conservative designs - CSA certified (# LR3902). Secondary: 360-0-360 V120 mA Filament winding 1: 5 V3 A Filament winding 2: 6.3 V3.5 A CT Mounting centers: 2.5" x 2.38" vertical mount Weight: 5.4 lbs. | $77.79 More Details |