Transformer - Hammond, Power, 350-0-350 V, 90 mA
Dual primary 115 VAC, 125 VAC, 60 Hz. Secondary DC current measured with cap. input filter, full wave (two diode) C.T., rectifier circuit. Enclosed, 4 hole chassis mount. Minimum 6 long leads. Class A insulation (105 degrees C). Hi-Pot test of 2000 V RMS. Conservative designs - CSA certified (# LR3902). Secondary: 350-0-350 V90 mA Filament winding 1: 5 V2 A Filament winding 2: 6.3 V3 A CT Mounting centers:2.25" x 2.81" horizontal Weight:4.6 lbs.
$84.39
More Details
Transformer - Hammond, Power, 325-0-325 V, 40 mA
Dual primary 115 VAC, 125 VAC, 60 Hz. Secondary DC current measured with cap. input filter, full wave (two diode) C.T., rectifier circuit. Enclosed, 4 hole chassis mount. Minimum 6 long leads. Class A insulation (105 degrees C). Hi-Pot test of 2000 V RMS. Conservative designs - CSA certified (# LR3902). Secondary: 325-0-325 V40 mA Filament winding 1: 5 V2 A Filament winding 2: 6.3 V2 A Mounting centers:2" x 2.5 horizontal Weight: 2.4 lbs
$65.77
More Details
Transformer - Hammond, Line Isolation, 90 VA
Hammond 169 Series Line Isolation Transformer 90 VA capacity, 650 secondary current ma. Primary 115 VAC, 60 Hz. Secondary 115 VAC Electrostatic shield between primary & secondary Connection by flexible leads, 8 minimum length 2" x 2.19" vertical Perfect for circuit isolation or "Classic" bias power supply CSA certified (# LR3902) 3.4 lbs
$53.08
More Details
Transformer - Hammond, Filament, 6.3 VCT, 10 A
Primary 115 VAC, 60 Hz. Center tapped secondary. Enclosed, 4 hole chassis mount. Minimum 6 long leads. Dual bobbin design - no electrostatic shield required. Class B insulation (130 degreesC) Hi-Pot test of 2000 V RMS. UL listed (# E50394) & CSA certified (# LR3902). Specifications Rating: 6.3 VCT10 A Mounting Centers: 1.69" x 2.00"vertical Weight:2.5 lbs
$39.40
More Details
Transformer - Hammond, Filament, 10 VCT, 10 A
Primary 115 VAC, 60 Hz. Center tapped secondary. Enclosed, 4 hole chassis mount. Minimum 6 long leads. Dual bobbin design - no electrostatic shield required. Class B insulation (130 degreesC) Hi-Pot test of 2000 V RMS. UL listed (# E50394) & CSA certified (# LR3902). Specifications Rating: 10 VCT10 A Mounting Centers: 2" x 2.19"vertical Weight:3.4 lbs
$43.95
More Details
Transformer - Hammond, Filament, 12.6 VCT, 2.5 A
Primary 115 VAC, 60 Hz. Center tapped secondary. Enclosed, 4 hole chassis mount. Minimum 6 long leads. Dual bobbin design - no electrostatic shield required. Class B insulation (130 degreesC) Hi-Pot test of 2000 V RMS. UL listed (# E50394) & CSA certified (# LR3902). Specifications Rating: 12.6 VCT2.5 A Mounting Centers: 1.5" x 1.56"vertical Mounting Centers: 1.4 lbs
$27.30
More Details
Transformer - Hammond, Filament, 5 VCT, 8 A
Primary 115 VAC, 60 Hz. Center tapped secondary. Enclosed, 4 hole chassis mount. Minimum 6 long leads. Dual bobbin design - no electrostatic shield required. Class B insulation (130 degreesC) Hi-Pot test of 2000 V RMS. UL listed (# E50394) & CSA certified (# LR3902). Specifications Rating: 5 VCT8 A Mounting Centers: 1.75" x 1.44"vertical Weight: 1.6lbs
$35.60
More Details
Transformer - Hammond, Line Isolation, 175 VA
Hammond 169 Series Line Isolation Transformer 175 VA capacity, 1300 secondary current ma. Primary 115 VAC, 60 Hz. Secondary 115 VAC Electrostatic shield between primary & secondary Connection by flexible leads, 8" minimum length 2.5 x 2.69"vertical mounting centers Perfect for circuit isolation or "Classic" bias power supply CSA certified (# LR3902) 6.0 lbs
$61.54
More Details