Transformer - Hammond, Power, 125-0-125 V, 100 mA
Dual primary 115 VAC, 125 VAC, 60 Hz. Secondary DC current measured with cap. input filter, full wave (two diode) C.T., rectifier circuit. Enclosed, 4 hole chassis mount. Minimum 6" long leads. Class A insulation (105 degrees C). Hi-Pot test of 2,000 V RMS. Conservative designs - CSA certified (# LR3902). Secondary: 125-0-125 V, 100 mA Filament winding: 6.3 V, 2 A Mounting centers: 1.75" x 1.44" vertical mount Weight: 1.7 lbs.
$48.18
More Details
Transformer - Hammond, Power, 275-0-275 V, 50 mA
Dual primary 115 VAC, 125 VAC, 60 Hz. Secondary DC current measured with cap. input filter, full wave (two diode) C.T., rectifier circuit. Enclosed, 4 hole chassis mount. Minimum 6" long leads. Class A insulation (105 degrees C). Hi-Pot test of 2,000 V RMS. Conservative designs - CSA certified (# LR3902). Secondary: 275-0-275V, 50 mA Filament winding 1: 5 V, 2 A Filament winding 2: 6.3 V, 1.5 A
$54.06
More Details
Transformer - Hammond, Power, 125-0-125 V, 100 mA
Universal Primary - 100, 110, 120, 200, 220, 240 VAC 50/60 Hz. High voltage secondary designed for full wave center tapped use. 50 VAC bias tap from high voltage secondary C.T. Black epoxy painted to match our P-T1650 series of output transformers . Class A insulation (105 degrees C). Hi-Pot test of 2,000 V RMS. Windings are concentric wound for low stray field and low noise. Secondary: 125-0-125 V, 100 mA Filament winding: 6.3 VCT, 2 A Mounting centers: 2" x 1.69" vertical mount Weight: 2.6 lbs.
$68.10
More Details
Transformer - Hammond, Power, 180-0-180 V, 250 mA
Universal Primary - 100, 110, 120, 200, 220, 240 VAC 50/60 Hz. High voltage secondary designed for full wave center tapped use. 50 VAC bias tap from high voltage secondary C.T. Black epoxy painted to match our P-T1650 series of output transformers . Class A insulation (105 degrees C). Hi-Pot test of 2,000 V RMS. Windings are concentric wound for low stray field and low noise. Secondary: 180-0-180 V, 465 mA Filament winding : 5 VCT, 3 A Mounting centers: 2.5" X 2.44" vertical mount Weight: 5.6 lbs.
$102.15
More Details
Transformer - Hammond, Power, 100-0-100 V, 100 mA
Dual primary 115 VAC, 125 VAC, 60 Hz. Secondary DC current measured with cap. input filter, full wave (two diode) C.T., rectifier circuit. Enclosed, 4 hole chassis mount. Minimum 6" long leads. Class A insulation (105 degrees C). Hi-Pot test of 2,000 V RMS. Conservative designs - CSA certified (# LR3902). Secondary: 100-0-100 V, 100 mA Filament winding: 5 V, 2 A Mounting centers: 1.5" x 1.56" vertical mount Weight: 1.5 lbs.
$47.38
More Details
Transformer - Hammond, Power, Replacement for Marshall
For JCM900, 50 watts, horizontal mount.
$138.78
More Details
Transformer - Hammond, Power, Low Voltage
Primary 117/234 VAC, 50/60 Hz. Secondary can be used as; a center tapped secondary, parallel connected or used individually. Open style Minimum 6 long leads. Dual bobbin design - no electrostatic shield required. Class B insulation (130 degreesC) for extra protection - UL listed as a Class A (105 degreeC) design Hi-Pot test of 2000V RMS UL listed (# E50394) Type 3AH CSA certified (# LR3902) Secondary VAC(RMS) :5V @ 3A(Series C.T.)2.5V @ 6A(Parallel) Mounting centers: 2.81" Weight: 1.06 lbs.
$27.22
More Details
Transformer - Hammond, Power, 425-0-425 V, 150 mA
Primary 115 VAC, 60 Hz. Secondary DC current measured with cap. input filter, full wave (two diode) C.T., rectifier circuit. Enclosed, 4 hole chassis mount. Minimum 6 long leads. Class A insulation (105 degrees C). Hi-Pot test of 2000 V RMS. Conservative designs - CSA certified (# LR3902). Secondary: 425-0-425 V150 mA Filament winding 1: 5 V3 A Filament winding 2: 6.3 V5 A CT Mounting centers: 2.5" x 2.69" vertical mount Weight: 6 lbs.
$102.84
More Details