Transformer - Hammond, High Voltage Plate & Filament, Vertical mount
  • Vertical Mount. For Horizontal Mount, see P-T263-Z
  • Primary 115 VAC, 60 Hz. - except as noted
  • Enclosed, 4 hole, chassis mount.
  • Minimum 6" long leads.
  • Units can be run full wave bridge or full wave C.T.
  • Class A insulation (105 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • Conservative designs - CSA certified (209651).
Starting at $69.95
Transformer - Hammond, Output, replacement for Marshall
  • Replacements for Marshall Amps
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Starting at $49.95
Transformer - Hammond, High Voltage Universal Plate & Filament, Vertical mount
  • Primary: Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz.
    • NOTE: units are designed to operate with BOTH primary windings engaged.
    • See primary wiring information under resources.
  • Bias Tap: 50 VAC tap from high voltage secondary C.T. (except part number P-T379WX - uses a separate 60VAC 0.2 Amp winding).
  • Highpot tested: 2,000 VAC
  • Faraday Copper Primary Shield: Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries (shield is internally grounded to the end bell).
  • Windings: Concentric wound for low stray field and low noise.
  • Models: This series is an upgrade from our P-T263-X range of units PLUS 2 models designed specifically for 300B tubes (Part Number P-T300BX) and 2A3 tubes (Part Number P-T302AX).
  • Finish: Black powder paint to match our P-T1650X series of output transformers Units can be run full wave bridge or full wave C.T.
  • Conservative designs - CSA certified (209651).
Starting at $93.97
Transformer - Hammond, Plate & Filament or Bias, 6.3 V auxiliary
  • Primary 115 VAC, 60 Hz.
  • Designed for small power or bias supplies, test equipment, preamps etc.
  • Models P-T261C6, P-T261E6, and P-T261G6 can also be used with full wave C.T. rectifiers.
  • Economical , two hole, channel bracket, chassis mount.
  • Minimum 5" long leads.
  • Convenient 6.3 filament/auxiliary winding.
Starting at $40.25
Filter Choke - Hammond, D.C. choke, Enclosed
  • Enclosed, 4-hole mount chokes
  • Tolerance of 15% on both inductance & resistance.
  • Inductances measured at rated D.C. current.
  • Minimum 8" long leads.
  • Units will exhibit less inductance at slightly higher currents or more at lower currents.
  • Perfect for high voltage power supply filtering, case matches power transformers & tube audio output transformers.
  • Units are vacuum impregnated with polyurethane varnish for quiet and long life operation.
  • For more sizes and voltages (open - bracket mount type) - see P-T154-P-T156-X
  • Operating temperature range is -40C to 85C
Starting at $52.95
Transformer - Fender® Replacement, Output, 50 W, 4 Ohm
Replacement for Bassman heads. Equivalent to #125A13A & #022871.
$53.58
Save 23%
Originally: $69.95
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 240 V
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120 for 120 V transformers, P-T290-Fender-120-UP for upgraded 120 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Starting at $63.25
Transformer - Hammond, Low Voltage / Filament, Open, 10 VCT
  • Open style, chassis mount transformers with a 115V 60Hz primary and a 10V center tapped secondary
Starting at $15.98
Note: P-T166F10: 3 is a special order item.
Transformer - Hammond, Output, Single-Ended, 30 W
  • Over designed for single ended tube output circuits (triode, tetrode or pentode tubes).
  • Enclosed (shielded), 4 slot, above chassis Type 'X' mounting.
  • Frequency response at least 20 Hz. to 20 Khz. at full rated power (± 1 db max. ref.
Starting at $213.10
Transformer - Hammond, Global Use, Dual Primary 115/230 VAC
  • Dual primary 115/230 VAC
  • 50/60 Hz. operation
  • Dual secondaries for series or parallel connections
  • 4,000 V RMS Hipot test
  • Class F insulation (155 degrees, C)
  • Chassis mount
  • Dual bobbin construction
  • Dual use terminals
  • C UL US recognized (E207860)
  • TUV Type Approved
  • CE certified to IEC 950 (Approved to EN 60-742 Safety Isolating Transformers)
$48.52
Transformer - Hammond, Low Voltage / Filament, Enclosed, 5 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 5 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $40.75
Transformer - Hammond, Output, replacement for Yorkville / Traynor
  • Replacements for Yorkville/Traynor Amps
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Starting at $58.13
Transformer - Hammond, Low Voltage / Filament, Open, 30 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 30 C.T.
  • Center tapped secondary.
  • Open style, channel bracket, two hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C).
  • Hi-Pot test of 2,000 V RMS.
  • UL listed (# E50394) & CSA certified (# LR3902).
Starting at $25.10
Note: P-T166E30: 4.5 is a special order item.
Transformer - Hammond, Low Voltage / Filament, Enclosed, 12.6 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 12 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $41.78
Transformer - Hammond, Low Voltage / Filament, Enclosed, 60 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 60 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$72.76
Transformer - Hammond, Audio Broadcast Quality, 850A Series
Deep-drawn steel case with tin plated finish, with two convenient 6-32 mounting studs with mounting hardware. Sealed case and wax potted core internally for stable characteristics and long life. Wide frequency response +/- 0.5 db max. from 20 Hz. to 20 Khz. (except units over 5K ohms impedance, may be down 1 db @ 20 Khz.) Insertion loss of apx. 1 db.
$161.22