P-TN-51XTransformer - Line Isolation, 35 VA, 115V, 300 mA, 1 x 115V

35VA chassis mount Power Transformer for isolating equipment from direct connection to the power line. It is constructed with non-concentrically wound coils. The primary and secondary are wound on separate arbors, then assembled on a laminate core side-by-side separated by insulation. This prevents electrical connection under normal or overload conditions between the primary and secondary windings. These units are designed with 1500V isolation between winding to winding and between winding and core. Materials and construction are rated for Class B insulation system.


$21.95
Click to read more
P-T169XSTransformer - Hammond, Line Isolation

Special Order Item

  • Primary 115VAC, 60 Hz.
  • Secondary 115VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for circuit isolation or "Classic" bias power supply
  • CSA certified (209651)
  • Remember - These units do NOT convert line frequency

Starting at $66.18
Note: special order items require additional lead time. See our page on special order items.
Note: this is a special order item.
Click to read more
P-T171XTransformer - Hammond, line isolation / plug & receptacle

Special Order Item

  • Primary 115VAC, 50 / 60 Hz., Secondary 115VAC
  • Provides complete circuit isolation.
  • Electrostatic shield between primary & secondary to greatly attenuate surges and noise.
  • Hi-pot tested to 2 KV RMS.
  • Circuit breaker in primary.
  • Standard 3-wire, grounded plug & receptacle.
  • Input (primary) connected to 5 foot long cord & standard North American plug (NEMA 5-15P).
  • Output (secondary) connected to 1 foot long "pig tail" cord, 3-wire, standard North American grounded receptacle (NEMA 5-15R).
  • North American Mark of Safety - C UL & UL listed (File #E211544)
  • Indoor use only
  • Remember - These units do NOT convert line frequency

Starting at $105.96
Note: special order items require additional lead time. See our page on special order items.
Note: this is a special order item.
Click to read more
P-TN-68XTransformer - Line Isolation, 50 VA, 115V, 435 mA, 2 x 115V

An Isolation Power Transformer for isolating equipment from direct connection to the power line. The transformer is constructed with non-concentrically wound coils. The primary and secondary are wound on separate arbors, then assembled on a laminate core side-by-side separated by insulation. This prevents electrical connection, under normal or overload conditions, between the primary and secondary windings.


$15.95
Click to read more
P-T850HAAudio Transformer - Hammond, 150/600Ω, Line Isolation

Special Order Item

  • 150/600 Ohm Primary Impedance
  • 300/1200 Ohm Secondary Impedance
  • Deep-drawn steel case with tin plated finish, with two convenient 6-32 mounting studs with mounting hardware.
  • Sealed case and wax potted core internally for stable characteristics and long life.
  • Wide frequency response ± 0.5 db max. from 20 Hz. to 20 Khz. (except units over 5K ohms impedance, may be down 1 db @ 20 Khz.)
  • Insertion loss of apx. 1 db.
  • Maximum power level +15 dbm. with specified characteristics, or higher levels with reduced low frequency performance.
  • Distortion is apx. 1.5% @ 20 Hz. under full power.
  • Electrostatic shield between pri. & sec. connected to the green lead.
  • Humbucking construction
  • Balanced split windings on pri. & sec. for circuit versatility. Primary may be used as a secondary and vice versa for impedance matching.
  • Lead length: Min. 4"

$146.22
Note: special order items require additional lead time. See our page on special order items.
Note: this is a special order item.
Click to read more
P-T109LTransformer - Hammond, 2W Audio Miniature Epoxy Potted

Special Order Item

Features:
  • Perfect for audio input, line matching, isolation or output transformer applications.
  • 2 watt (± 1.5 db, 300Hz. - 50 KHz.).
  • Epoxy potted in an attractive black molded case, Pin type P.C. board mount (min. 0.187" length).
  • Power level ratings are maximum at lowest frequency rating
  • Power can be increased slightly at higher frequencies.
  • Will withstand soldering for 10 sec. @ 260 degrees C, ambient temp. 85 degrees C max.
$33.14
Note: special order items require additional lead time. See our page on special order items.
Note: this is a special order item.
Click to read more
P-T169CTransformer - Hammond, Isolation, 100VA

Special Order Item

Capacity: 100 VA
Features:
  • Primary 115VAC, 60 Hz.
  • Secondary taps @ 90, 100, 110, 115, 120 & 130VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for critical line voltage needs (examples: older "classic" tube equipment or Japanese 100V equipment).
  • CSA certified (# LR3902)
  • Remember - These units do NOT convert line frequency
$73.27
Note: special order items require additional lead time. See our page on special order items.
Note: this is a special order item.
Click to read more
P-T298DTTransformer - Hammond, Line Step Up Isolation, Toroidal, 500 VA

Special Order Item

Capacity: 500 VA
Dimensions: 9" long by 6" wide by 4" height
Features:
  • Primary 120VAC, 50/60 Hz., Secondary 240VAC.
  • Provides circuit isolation.
  • Toroidal transformer for high isolation, low noise, light weight cool operation and low profile.
  • 50 or 60 Hz.
$327.56
Note: special order items require additional lead time. See our page on special order items.
Note: this is a special order item.
Click to read more
P-T298G4Transformer - Hammond, Line European grounded adaptor plug

Special Order Item

Europeon plug type Used in: Austria; Belgium; Finland; France; Germany; Middle East; Netherlands; Norway; Parts of Africa, Asia ,South America, China, Tahiti and Caribbean; Sweden Features:



  • For use with Hammond transformers
  • Heavy duty design with plastic shell & double wipe contacts.
  • Indoor use only.
  • Allows for ground connection between equipment and international power sources.
  • Adaptors do not affect voltages, they are a mechanical device only to match foreign "pin-outs" of receptacles and/or plugs.

$10.38
Note: special order items require additional lead time. See our page on special order items.
Note: this is a special order item.
Click to read more
Don't see a product you're looking for? Send us your product suggestions!