Transformers & Chokes

Transformer - Hammond, Isolation, 100VA
Capacity: 100 VA
Features:
  • Primary 115VAC, 60 Hz.
  • Secondary taps @ 90, 100, 110, 115, 120 & 130VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for critical line voltage needs (examples: older "classic" tube equipment or Japanese 100V equipment).
  • CSA certified (# LR3902)
  • Remember - These units do NOT convert line frequency
$84.95
Transformer - Hammond, Plate & Filament
  • Universal primary with taps for 100, 120, 220 or 240 VAC, 50 / 60 Hz. (Except the 260A6 which is 117V, 50/60 Hz only)
  • Designed for preamps, low power amps, general replacement, test equipment, etc.
  • Economical, open frame, chassis mount - two hole (.187 dia. = G) channel bracket (figure #1) or four hole mounting (figure #2).
  • Units include a Faraday shield between the primary and secondary windings. Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries.
  • Minimum 5" long leads.
  • For more selection check out our P-T300-X series of universal plate & filament transformers.
Starting at $81.68
Transformer - Hammond, Low Voltage / Filament, Open, 72 VCT
Open style, chassis mount transformers with a 117V 50/60Hz primary and a 72V center tapped secondary.
$79.07
Transformer - Hammond, Isolation, 115V
  • Primary 115VAC, 60 Hz.
  • Secondary 115VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for circuit isolation or "Classic" bias power supply
  • CSA certified (209651)
  • Remember - These units do NOT convert line frequency
Starting at $76.73
Transformer - Hammond, Low Voltage / Filament, Enclosed, 60 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 60 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$76.40
Transformer - Hammond, Low Voltage / Filament, Open, 48 VCT
Open style, chassis mount transformers with a 117V 50/60Hz primary and a 48V center tapped secondary.
$72.52
Transformer - Hammond, Low Voltage / Filament, Enclosed, 10 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 10 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$70.67
Transformer - Hammond, Toroidal Power, 30V / 60V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 60 V series, 30 V parallel secondary.
Starting at $70.53
Transformer - Hammond, High Voltage Plate & Filament, Vertical mount
  • Vertical Mount. For Horizontal Mount, see P-T263-Z
  • Primary 115 VAC, 60 Hz. - except as noted
  • Enclosed, 4 hole, chassis mount.
  • Minimum 6" long leads.
  • Units can be run full wave bridge or full wave C.T.
  • Class A insulation (105 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • Conservative designs - CSA certified (209651).
Starting at $69.95
Partially Out of Stock
Note: P-T274AX: 720 V C.T. @ 138 mA is a special order item.
Transformer - Hammond, Low Voltage / Filament, Enclosed, 50 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 50 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$67.95
Transformer - Hammond, Toroidal Power, 12V / 24V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 24 V series, 12 V parallel secondary.
Starting at $63.65
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 240 V
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120 for 120 V transformers, P-T290-Fender-120-UP for upgraded 120 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Starting at $63.25
Transformer - Hammond, Toroidal Power, 240V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 240V secondary.
Starting at $61.85
Transformer - Hammond, Toroidal Power, 15V / 30V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 30 V series, 15 V parallel secondary.
Starting at $61.85
Transformer - Hammond, Toroidal Power, 117V / 234V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 234 V series, 117 V parallel secondary.
Starting at $61.85
Transformer - Hammond, Toroidal Power, 22V / 44V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 44 V series, 22 V parallel secondary.
Starting at $61.85
Transformer - Hammond, Low Voltage / Filament, Enclosed, 120 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 120 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$61.15
Transformer - Power, 120V Primary, 325/275V / 6.3VCT / 5V Secondary, for Fender® Champ
Power transformer replacement for the Fender® part numbers 125P1B, 022772, and 66079B. This transformer offers two different B+ options for lower voltage or higher voltage builds. This transformer is used in versions of the:
  • Bronco
  • Champ
  • Princeton
  • Princeton Reverb
  • Vibro Champ

Features
  • 275V or 325V (650/550 VCT) B+ options at 100mA
  • Center tapped 6.3V filament at 2.25A
  • 5V filament supply at 3A
  • For 120V 60Hz primary
  • Standard 2.5” x 2” mounting centers
$59.95
Transformer - Hammond, Low Voltage / Filament, Open, 42 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 42V center tapped secondary.
$58.00
Transformer - Hammond, Toroidal Power, 6V / 12V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 12 V series, 6 V parallel secondary.mary, 50/60 Hz. operation.
Starting at $57.68
Transformer - Hammond, Toroidal Power, 110V / 220V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 220 V series, 110 V parallel secondary.
Starting at $57.68
Transformer - Hammond, Toroidal Power, 18V / 36V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 36 V series, 18 V parallel secondary.
Starting at $57.68
Transformer - Hammond, Toroidal Power, 9V / 18V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 18 V series, 9 V parallel secondary.
Starting at $57.68
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 120 V
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120-UP for upgraded 120 V transformers, P-T290-FENDER-240 for 240 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Starting at $57.49