Transformer - Hammond, Power, Low Voltage PC Mount Size: 48 VA
Secondary Series: 40V C.T. @ 1.2A
Secondary Parallel: 20V @ 2.4 A
Features:
Low profile mounting, dual - split bobbin design. Low primary to secondary coupling, balanced windings, no electrostatic shield required and low EMF radiation due to semi-toroidal design. Universal dual primary 115/230V - 50/60 Hz. High insulation - Hipot of 1,750V RMS. Class B insulation - 130 degrees C. C UL US recognized. $25.05
Click to read more
Transformer - Hammond, Plate & Filament Universal primary with taps for 100, 120, 220 or 240 VAC, 50 / 60 Hz. (Except the 260A6 which is 117V, 50/60 Hz only) Designed for preamps, low power amps, general replacement, test equipment, etc. Economical, open frame, chassis mount - two hole (.187 dia. = G) channel bracket (figure #1) or four hole mounting (figure #2). Units include a Faraday shield between the primary and secondary windings. Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries. Minimum 5" long leads. For more selection check out our P-T300-X series of universal plate & filament transformers.
Starting at $74.84
Click to read more
Transformer - Hammond, Power, Low voltage, 14V/0.5A Specifications:
Size: 7 VA Dual Primary: 117 VAC, 234VAC, 50/60 Hz. Secondary VAC RMS Series: 14V @ 0.5 A Secondary VAC RMS Parallel: 7V @ 1 A
Features:
Primary 117/234 VAC, 50/60 Hz. Dual secondaries Secondaries can be used as; a center tapped secondary, parallel connected or used individually Units are designed for use with all windings engaged. Open style. Minimum 6" long leads. Dual bobbin design - no electrostatic shield required. Class B insulation (130 degrees, C) for extra p
$23.63
Click to read more
Transformer - Hammond, Power, Low voltage, 36V/0.5A Specifications:
Size: 18 VA Dual Primary: 117 VAC, 234VAC, 50/60 Hz. Secondary VAC RMS Series: 36V @ 0.5 A Secondary VAC RMS Parallel: 18V @ 1 A
Features:
Primary 117/234 VAC, 50/60 Hz. Dual secondaries Secondaries can be used as; a center tapped secondary, parallel connected or used individually Units are designed for use with all windings engaged. Open style. Minimum 6" long leads. Dual bobbin design - no electrostatic shield required. Class B insulation (130 degrees, C) for extra
$31.50
Click to read more
Transformer - Hammond, Power, Low voltage, 14V/1A Specifications:
Size: 14 VA Dual Primary: 117 VAC, 234VAC, 50/60 Hz. Secondary VAC RMS Series: 14V @ 1 A Secondary VAC RMS Parallel: 7V @ 2 A
Features:
Primary 117/234 VAC, 50/60 Hz. Dual secondaries Secondaries can be used as; a center tapped secondary, parallel connected or used individually Units are designed for use with all windings engaged. Open style. Minimum 6" long leads. Dual bobbin design - no electrostatic shield required. Class B insulation (130 degrees, C) for extra pr
$29.54
Click to read more
Transformer - Hammond, Power, Low voltage, 48V/1A Specifications:
Size: 48 VA Dual Primary: 117 VAC, 234VAC, 50/60 Hz. Secondary VAC RMS Series: 48V @ 1 A Secondary VAC RMS Parallel: 24V @ 2 A
Features:
Primary 117/234 VAC, 50/60 Hz. Dual secondaries Secondaries can be used as; a center tapped secondary, parallel connected or used individually Units are designed for use with all windings engaged. Open style. Minimum 6" long leads. Dual bobbin design - no electrostatic shield required. Class B insulation (130 degrees, C) for extra p
$29.54
Click to read more
Transformer - Hammond, Power, Low voltage, 16V/3A Specifications:
Size: 48 VA Dual Primary: 117 VAC, 234VAC, 50/60 Hz. Secondary VAC RMS Series: 16V @ 3 A Secondary VAC RMS Parallel: 8V @ 6 A
Features:
Primary 117/234 VAC, 50/60 Hz. Dual secondaries Secondaries can be used as; a center tapped secondary, parallel connected or used individually Units are designed for use with all windings engaged. Open style. Minimum 6" long leads. Dual bobbin design - no electrostatic shield required. Class B insulation (130 degrees, C) for extra pr
$31.50
Click to read more
Transformer - Hammond, Power, Low voltage, 12.6V/4A Specifications:
Size: 50.4 VA Dual Primary: 117 VAC, 234VAC, 50/60 Hz. Secondary VAC RMS Series: 12.6V @ 4 A Secondary VAC RMS Parallel: 6.3V @ 8 A
Features:
Primary 117/234 VAC, 50/60 Hz. Dual secondaries Secondaries can be used as; a center tapped secondary, parallel connected or used individually Units are designed for use with all windings engaged. Open style. Minimum 6" long leads. Dual bobbin design - no electrostatic shield required. Class B insulation (130 degrees, C) for ex
$33.47
Click to read more
Transformer - Hammond, Power, Low voltage, 6.3V/6A Specifications:
Size: 37.8 VA Dual Primary: 117 VAC, 234VAC, 50/60 Hz. Secondary VAC RMS Series: 6.3V @ 6 A Secondary VAC RMS Parallel: 3.15V @ 12 A
Features:
Primary 117/234 VAC, 50/60 Hz. Dual secondaries Secondaries can be used as; a center tapped secondary, parallel connected or used individually Units are designed for use with all windings engaged. Open style. Minimum 6" long leads. Dual bobbin design - no electrostatic shield required. Class B insulation (130 degrees, C) for e
$39.38
Click to read more
Transformer - Hammond, Line Step Up Isolation, Toroidal, 500 VA Capacity: 500 VA
Dimensions: 9" long by 6" wide by 4" height
Features:
Primary 120VAC, 50/60 Hz., Secondary 240VAC. Provides circuit isolation. Toroidal transformer for high isolation, low noise, light weight cool operation and low profile. 50 or 60 Hz. $270.24