Transformers & Chokes
Transformer - Hammond, Low Voltage / Filament, Open, 22 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 22V center tapped secondary.
$42.13
Transformer - Hammond, Low Voltage / Filament, Open, 42 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 42V center tapped secondary.
$58.00
Transformer - Hammond, Low Voltage / Filament, Open, 48 VCT
Open style, chassis mount transformers with a 117V 50/60Hz primary and a 48V center tapped secondary.
$72.52
Transformer - Hammond, Low Voltage / Filament, Open, 72 VCT
Open style, chassis mount transformers with a 117V 50/60Hz primary and a 72V center tapped secondary.
$79.07
Transformer - Hammond, Low Voltage / Filament, Enclosed, 120 VCT
- Primary 115 VAC, 60 Hz.
- Secondary 120 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
$61.15
Transformer - Hammond, Low Voltage / Filament, Enclosed, 36 VCT
- Primary 115 VAC, 60 Hz.
- Secondary 36 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
$49.08
Transformer - Hammond, Low Voltage / Filament, Enclosed, 50 VCT
- Primary 115 VAC, 60 Hz.
- Secondary 50 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
$67.95
Transformer - Hammond, Low Voltage / Filament, Enclosed, 60 VCT
- Primary 115 VAC, 60 Hz.
- Secondary 60 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
$76.40
Transformer - Hammond, Low Voltage / Filament, Enclosed, 10 VCT
- Primary 115 VAC, 60 Hz.
- Secondary 10 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
$70.67
Transformer - Hammond, Low Voltage / Filament, Enclosed, 12.6 VCT
- Primary 115 VAC, 60 Hz.
- Secondary 12 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
Starting at $43.87
Transformer - Hammond, Low Voltage / Filament, Enclosed, 25 VCT
- Primary 115 VAC, 60 Hz.
- Secondary 25 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
Starting at $43.08
Transformer - Hammond, Low Voltage / Filament, Enclosed, 5 VCT
- Primary 115 VAC, 60 Hz.
- Secondary 5 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
Starting at $42.78
Transformer - Hammond, Low Voltage / Filament, Enclosed, 6.3 VCT
- Primary 115 VAC, 60 Hz.
- Secondary 6.3 C.T.
- All secondaries center tapped, VAC (RMS)
- Enclosed, 4 hole chassis mount.
- Minimum 6" long leads.
- Dual bobbin design - no electrostatic shield required.
- Class B insulation (130 degrees C).
- Hi-Pot test of 2,000V RMS.
- UL listed (# E50394) & CSA certified (209651).
Starting at $44.23
Transformer - Hammond, Isolation, 100VA
Capacity: 100 VA
Features:
Features:
- Primary 115VAC, 60 Hz.
- Secondary taps @ 90, 100, 110, 115, 120 & 130VAC
- Electrostatic shield between primary & secondary
- Connection by flexible leads, 8" minimum length
- Perfect for critical line voltage needs (examples: older "classic" tube equipment or Japanese 100V equipment).
- CSA certified (# LR3902)
- Remember - These units do NOT convert line frequency
$84.95
Transformer - Hammond, Isolation, 115V
- Primary 115VAC, 60 Hz.
- Secondary 115VAC
- Electrostatic shield between primary & secondary
- Connection by flexible leads, 8" minimum length
- Perfect for circuit isolation or "Classic" bias power supply
- CSA certified (209651)
- Remember - These units do NOT convert line frequency
Starting at $76.73
Transformer - Hammond, Isolation / plug & receptacle
- Primary 115VAC, 50 / 60 Hz., Secondary 115VAC
- Provides complete circuit isolation.
- Electrostatic shield between primary & secondary to greatly attenuate surges and noise.
- Hi-pot tested to 2 KV RMS.
- Circuit breaker in primary.
- Standard 3-wire, grounded plug & receptacle.
- Input (primary) connected to 5 foot long cord & standard North American plug (NEMA 5-15P).
- Output (secondary) connected to 1 foot long "pig tail" cord, 3-wire, standard North American grounded receptacle (NEMA 5-15R).
- North American Mark of Safety - C UL & UL listed (File #E211544)
- Indoor use only
- Remember - These units do NOT convert line frequency
Starting at $122.85
Transformer - Hammond, Step-Up, 500VA
Capacity: 500VA Features:
- Single winding does not provide isolation, for use where equipment is already isolated and only voltage change is required.
- World wide applications, 50 or 60 Hz.
$186.40
Transformer - Hammond, Global Use, Dual Primary 115/230 VAC
- Dual primary 115/230 VAC
- 50/60 Hz. operation
- Dual secondaries for series or parallel connections
- 4,000 V RMS Hipot test
- Class F insulation (155 degrees, C)
- Chassis mount
- Dual bobbin construction
- Dual use terminals
- C UL US recognized (E207860)
- TUV Type Approved
- CE certified to IEC 950 (Approved to EN 60-742 Safety Isolating Transformers)
$50.95
Transformer - Hammond, Low Voltage, Single Primary, 10V 5A
Current: 5 A
VA Rating: 50
Features:
Special Order Item
Secondary VAC: 10V C.T.Current: 5 A
VA Rating: 50
Features:
- Single Primary 115VAC
- Operates on 50/60 Hz.
- Combination solder or quick connect terminals.
- Split bobbin construction eliminates the need for an electrostatic shield.
- Hi-pot tested to 2 KV RMS.
- Economical open style, channel frame - chassis mount design
- UL recognized & CSA certified.
$24.15
Transformer - Hammond, Low Voltage, Dual Primary, 12.6V 4A
Current: 4 A
VA Rating: 50.4
Features:
Special Order Item
Secondary VAC: 12.6V C.T.Current: 4 A
VA Rating: 50.4
Features:
- Dual Primary 115/230VAC
- Operates on 50/60 Hz.
- Combination solder or quick connect terminals.
- Split bobbin construction eliminates the need for an electrostatic shield.
- Hi-pot tested to 2 KV RMS.
- Economical open style, channel frame - chassis mount design
- UL recognized & CSA certified.
$21.73
Transformer - Hammond, Low Voltage, Single Primary, 120VCT
Special Order Item
- Single Primary 115VAC
- Operates on 50/60 Hz.
- Combination solder or quick connect terminals.
- Split bobbin construction eliminates the need for an electrostatic shield.
- Hi-pot tested to 2 KV RMS.
- Economical open style, channel frame - chassis mount design
- UL recognized & CSA certified.
Starting at $11.42
Transformer - Hammond, Power, 115V/230V, 230V/50mA, 12VA
Special Order Item
Low profile mounting, dual - split bobbin design. 12VA.
$18.60
Transformer - Hammond, Power, Low Voltage PC Mount
Size: 48 VA
Secondary Series: 40V C.T. @ 1.2A
Secondary Parallel: 20V @ 2.4 A
Features:
Secondary Series: 40V C.T. @ 1.2A
Secondary Parallel: 20V @ 2.4 A
Features:
- Low profile mounting, dual - split bobbin design.
- Low primary to secondary coupling, balanced windings, no electrostatic shield required and low EMF radiation due to semi-toroidal design.
- Universal dual primary 115/230V - 50/60 Hz.
- High insulation - Hipot of 1,750V RMS.
- Class B insulation - 130 degrees C.
- C UL US recognized.
$37.18
Transformer - Hammond, Plate & Filament
- Universal primary with taps for 100, 120, 220 or 240 VAC, 50 / 60 Hz. (Except the 260A6 which is 117V, 50/60 Hz only)
- Designed for preamps, low power amps, general replacement, test equipment, etc.
- Economical, open frame, chassis mount - two hole (.187 dia. = G) channel bracket (figure #1) or four hole mounting (figure #2).
- Units include a Faraday shield between the primary and secondary windings. Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries.
- Minimum 5" long leads.
- For more selection check out our P-T300-X series of universal plate & filament transformers.
Starting at $81.68