Transformers & Chokes

Transformer - Hammond, Low Voltage / Filament, Open, 120 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 120V center tapped secondary.
$34.25
Transformer - Hammond, Low Voltage / Filament, Open, 100 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 100V center tapped secondary.
$44.80
Transformer - Hammond, Low Voltage / Filament, Open, 60 VCT
  • Open style, chassis mount transformers with a 115V 60Hz primary and a 60V center tapped secondary.
$31.63
Transformer - Hammond, Low Voltage / Filament, Open, 80 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and an 80V center tapped secondary.
$39.53
Transformer - Hammond, Low Voltage / Filament, Open, 33 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 33V center tapped secondary.
$34.83
Transformer - Hammond, Low Voltage / Filament, Open, 35 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 35V center tapped secondary.
$44.80
Transformer - Hammond, Low Voltage / Filament, Open, 22 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 22V center tapped secondary.
$42.13
Transformer - Hammond, Low Voltage / Filament, Open, 42 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 42V center tapped secondary.
$58.00
Transformer - Hammond, Low Voltage / Filament, Open, 48 VCT
Open style, chassis mount transformers with a 117V 50/60Hz primary and a 48V center tapped secondary.
$72.52
Transformer - Hammond, Low Voltage / Filament, Open, 72 VCT
Open style, chassis mount transformers with a 117V 50/60Hz primary and a 72V center tapped secondary.
$79.07
Transformer - Hammond, Low Voltage / Filament, Enclosed, 120 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 120 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$61.15
Transformer - Hammond, Low Voltage / Filament, Enclosed, 36 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 36 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$49.08
Transformer - Hammond, Low Voltage / Filament, Enclosed, 50 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 50 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$67.95
Transformer - Hammond, Low Voltage / Filament, Enclosed, 60 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 60 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$76.40
Transformer - Hammond, Low Voltage / Filament, Enclosed, 10 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 10 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
$70.67
Transformer - Hammond, Low Voltage / Filament, Enclosed, 12.6 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 12 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $43.87
Transformer - Hammond, Low Voltage / Filament, Enclosed, 25 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 25 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $43.08
Transformer - Hammond, Low Voltage / Filament, Enclosed, 5 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 5 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $42.78
Transformer - Hammond, Low Voltage / Filament, Enclosed, 6.3 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 6.3 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $44.23
Note: P-T167U6: 16 A is a special order item.
Transformer - Hammond, Isolation, 100VA
Capacity: 100 VA
Features:
  • Primary 115VAC, 60 Hz.
  • Secondary taps @ 90, 100, 110, 115, 120 & 130VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for critical line voltage needs (examples: older "classic" tube equipment or Japanese 100V equipment).
  • CSA certified (# LR3902)
  • Remember - These units do NOT convert line frequency
$84.95
Transformer - Hammond, Isolation, 115V
  • Primary 115VAC, 60 Hz.
  • Secondary 115VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for circuit isolation or "Classic" bias power supply
  • CSA certified (209651)
  • Remember - These units do NOT convert line frequency
Starting at $76.73
Transformer - Hammond, Isolation / plug & receptacle
  • Primary 115VAC, 50 / 60 Hz., Secondary 115VAC
  • Provides complete circuit isolation.
  • Electrostatic shield between primary & secondary to greatly attenuate surges and noise.
  • Hi-pot tested to 2 KV RMS.
  • Circuit breaker in primary.
  • Standard 3-wire, grounded plug & receptacle.
  • Input (primary) connected to 5 foot long cord & standard North American plug (NEMA 5-15P).
  • Output (secondary) connected to 1 foot long "pig tail" cord, 3-wire, standard North American grounded receptacle (NEMA 5-15R).
  • North American Mark of Safety - C UL & UL listed (File #E211544)
  • Indoor use only
  • Remember - These units do NOT convert line frequency
Starting at $122.85
Transformer - Hammond, Output, replacement for Orange Rocker 30
Hammond output transformer - replacement for Orange Rocker 30 Specifications: Part No. Pri Ohms Sec Ohms Amplifier Type Watts Bobbin/Paper Winding Equivalent To P-T1750ORF 6,000 C.T. 8, 16 Push-Pull 35 W Bobbin OT199SL
$82.23
Transformer - Hammond, Output, replacement for Fender
  • Replacements for Fender Amps
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Starting at $33.95