Transformer - Hammond, Isolation, 100VA
Capacity: 100 VA
Features:
  • Primary 115VAC, 60 Hz.
  • Secondary taps @ 90, 100, 110, 115, 120 & 130VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for critical line voltage needs (examples: older "classic" tube equipment or Japanese 100V equipment).
  • CSA certified (# LR3902)
  • Remember - These units do NOT convert line frequency
$84.95
Transformer - Hammond, Isolation, 115V
  • Primary 115VAC, 60 Hz.
  • Secondary 115VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for circuit isolation or "Classic" bias power supply
  • CSA certified (209651)
  • Remember - These units do NOT convert line frequency
Starting at $76.73
Transformer - Hammond, Isolation / plug & receptacle
  • Primary 115VAC, 50 / 60 Hz., Secondary 115VAC
  • Provides complete circuit isolation.
  • Electrostatic shield between primary & secondary to greatly attenuate surges and noise.
  • Hi-pot tested to 2 KV RMS.
  • Circuit breaker in primary.
  • Standard 3-wire, grounded plug & receptacle.
  • Input (primary) connected to 5 foot long cord & standard North American plug (NEMA 5-15P).
  • Output (secondary) connected to 1 foot long "pig tail" cord, 3-wire, standard North American grounded receptacle (NEMA 5-15R).
  • North American Mark of Safety - C UL & UL listed (File #E211544)
  • Indoor use only
  • Remember - These units do NOT convert line frequency
Starting at $122.85
Transformer - Hammond, Output, replacement for Orange Rocker 30
Hammond output transformer - replacement for Orange Rocker 30 Specifications: Part No. Pri Ohms Sec Ohms Amplifier Type Watts Bobbin/Paper Winding Equivalent To P-T1750ORF 6,000 C.T. 8, 16 Push-Pull 35 W Bobbin OT199SL
$82.23
Transformer - Hammond, Output, replacement for Fender
  • Replacements for Fender Amps
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Starting at $33.95
Transformer - Hammond, Output, replacement for Marshall
  • Replacements for Marshall Amps
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Starting at $49.95
Transformer - Hammond, Output, replacement for Vox
  • Replacements for Vox Amps
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Starting at $91.00
Save 23%
Originally: $118.72
Transformer - Hammond, Output, replacement for Yorkville / Traynor
  • Replacements for Yorkville/Traynor Amps
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Starting at $61.03
Note: P-T1750G: 92105 50 W General is a special order item.
Transformer - Hammond, Step-Up, 500VA
Capacity: 500VA Features:
  • Single winding does not provide isolation, for use where equipment is already isolated and only voltage change is required.
  • World wide applications, 50 or 60 Hz.
$186.40
Transformer - Hammond, Global Use, Dual Primary 115/230 VAC
  • Dual primary 115/230 VAC
  • 50/60 Hz. operation
  • Dual secondaries for series or parallel connections
  • 4,000 V RMS Hipot test
  • Class F insulation (155 degrees, C)
  • Chassis mount
  • Dual bobbin construction
  • Dual use terminals
  • C UL US recognized (E207860)
  • TUV Type Approved
  • CE certified to IEC 950 (Approved to EN 60-742 Safety Isolating Transformers)
$50.95
Transformer - Hammond, Low Voltage, Single Primary, 10V 5A
Special Order Item
Secondary VAC: 10V C.T.
Current: 5 A
VA Rating: 50
Features:
  • Single Primary 115VAC
  • Operates on 50/60 Hz.
  • Combination solder or quick connect terminals.
  • Split bobbin construction eliminates the need for an electrostatic shield.
  • Hi-pot tested to 2 KV RMS.
  • Economical open style, channel frame - chassis mount design
  • UL recognized & CSA certified.
$24.15
Note: special order items require additional lead time. See our page on special order items.
Transformer - Hammond, Low Voltage, Dual Primary, 12.6V 4A
Special Order Item
Secondary VAC: 12.6V C.T.
Current: 4 A
VA Rating: 50.4
Features:
  • Dual Primary 115/230VAC
  • Operates on 50/60 Hz.
  • Combination solder or quick connect terminals.
  • Split bobbin construction eliminates the need for an electrostatic shield.
  • Hi-pot tested to 2 KV RMS.
  • Economical open style, channel frame - chassis mount design
  • UL recognized & CSA certified.
$21.73
Note: special order items require additional lead time. See our page on special order items.
Transformer - Hammond, Low Voltage, Single Primary, 120VCT
Special Order Item
  • Single Primary 115VAC
  • Operates on 50/60 Hz.
  • Combination solder or quick connect terminals.
  • Split bobbin construction eliminates the need for an electrostatic shield.
  • Hi-pot tested to 2 KV RMS.
  • Economical open style, channel frame - chassis mount design
  • UL recognized & CSA certified.
Starting at $11.42
Note: special order items require additional lead time. See our page on special order items.
Filter Choke - Hammond, D.C. choke, Enclosed
  • Enclosed, 4-hole mount chokes
  • Tolerance of 15% on both inductance & resistance.
  • Inductances measured at rated D.C. current.
  • Minimum 8" long leads.
  • Units will exhibit less inductance at slightly higher currents or more at lower currents.
  • Perfect for high voltage power supply filtering, case matches power transformers & tube audio output transformers.
  • Units are vacuum impregnated with polyurethane varnish for quiet and long life operation.
  • For more sizes and voltages (open - bracket mount type) - see P-T154-P-T156-X
  • Operating temperature range is -40C to 85C
Starting at $47.57
Save 10%
Originally: $52.95
Note: P-T193T: 0.05 H / 2 A is a special order item.
Transformer - Hammond, Power, 115V/230V, 230V/50mA, 12VA
Special Order Item
Low profile mounting, dual - split bobbin design. 12VA.
$18.60
Note: special order items require additional lead time. See our page on special order items.
Transformer - Hammond, Power, Low Voltage PC Mount
Size: 48 VA
Secondary Series: 40V C.T. @ 1.2A
Secondary Parallel: 20V @ 2.4 A
Features:
  • Low profile mounting, dual - split bobbin design.
  • Low primary to secondary coupling, balanced windings, no electrostatic shield required and low EMF radiation due to semi-toroidal design.
  • Universal dual primary 115/230V - 50/60 Hz.
  • High insulation - Hipot of 1,750V RMS.
  • Class B insulation - 130 degrees C.
  • C UL US recognized.
$37.18
Transformer - Hammond, Plate & Filament
  • Universal primary with taps for 100, 120, 220 or 240 VAC, 50 / 60 Hz. (Except the 260A6 which is 117V, 50/60 Hz only)
  • Designed for preamps, low power amps, general replacement, test equipment, etc.
  • Economical, open frame, chassis mount - two hole (.187 dia. = G) channel bracket (figure #1) or four hole mounting (figure #2).
  • Units include a Faraday shield between the primary and secondary windings. Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries.
  • Minimum 5" long leads.
  • For more selection check out our P-T300-X series of universal plate & filament transformers.
Starting at $81.68
Transformer - Hammond, Plate & Filament or Bias, 6.3 V auxiliary
  • Primary 115 VAC, 60 Hz.
  • Designed for small power or bias supplies, test equipment, preamps etc.
  • Models P-T261C6, P-T261E6, and P-T261G6 can also be used with full wave C.T. rectifiers.
  • Economical , two hole, channel bracket, chassis mount.
  • Minimum 5" long leads.
  • Convenient 6.3 filament/auxiliary winding.
Starting at $40.25
Note:
P-T262F6:120 V @ 140 mA
P-T261M6:215 V @ 269 mA
are special order items.
Note: some of these items are special order items.
Transformer - Hammond, Plate & Filament or Bias, 12.6V auxiliary
  • Primary 115 VAC, 60 Hz.
  • Designed for small power or bias supplies, test equipment, preamps etc.
  • Economical , two hole, channel bracket, chassis mount.
  • Minimum 5" long leads.
  • Convenient 12.6 filament/auxiliary winding.
$46.08
Transformer - Hammond, High Voltage Plate & Filament, Vertical mount
  • Vertical Mount. For Horizontal Mount, see P-T263-Z
  • Primary 115 VAC, 60 Hz. - except as noted
  • Enclosed, 4 hole, chassis mount.
  • Minimum 6" long leads.
  • Units can be run full wave bridge or full wave C.T.
  • Class A insulation (105 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • Conservative designs - CSA certified (209651).
Starting at $64.90
Save 7%
Originally: $69.95
Partially Out of Stock
Note: P-T274AX: 720 V C.T. @ 138 mA is a special order item.
Transformer - Hammond, High Voltage Plate & Filament, Horizontal mount
  • Horizontal mount. For Vertical Mount, see P-T263-X
  • Primary 117 VAC, 50/60 Hz. - except as noted
  • Enclosed, 4 hole, chassis mount.
  • Minimum 6" long leads.
  • Units can be run full wave bridge or full wave C.T.
  • Class A insulation (105 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • Conservative designs - CSA certified (209651).
  • For Vertical Mount, see P-T263-X
Starting at $88.07
Save 7%
Originally: $95.10
Transformer - Hammond, Power, Low voltage, 14V/0.5A
Specifications:
  • Size: 7 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 14V @ 0.5 A
  • Secondary VAC RMS Parallel: 7V @ 1 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra p
$33.22
Transformer - Hammond, Power, Low voltage, 36V/0.5A
Specifications:
  • Size: 18 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 36V @ 0.5 A
  • Secondary VAC RMS Parallel: 18V @ 1 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra
$44.30
Transformer - Hammond, Power, Low voltage, 14V/1A
Specifications:
  • Size: 14 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 14V @ 1 A
  • Secondary VAC RMS Parallel: 7V @ 2 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra pr
$41.52