Transformer - Hammond, Power, Low voltage, 48V/1A
Specifications:
  • Size: 48 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 48V @ 1 A
  • Secondary VAC RMS Parallel: 24V @ 2 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra p
$41.52
Transformer - Hammond, Power, Low voltage, 16V/3A
Specifications:
  • Size: 48 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 16V @ 3 A
  • Secondary VAC RMS Parallel: 8V @ 6 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra pr
$44.30
Transformer - Hammond, Power, Low V Primary / Secondary, 5V/3A
Specifications:
  • Size: 15 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 5V @ 3 A
  • Secondary VAC RMS Parallel: 2.5V @ 6 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra p
$41.52
Transformer - Hammond, Power, Low voltage, 12.6V/4A
Specifications:
  • Size: 50.4 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 12.6V @ 4 A
  • Secondary VAC RMS Parallel: 6.3V @ 8 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for ex
$47.02
Transformer - Hammond, Power, Low voltage, 6.3V/6A
Specifications:
  • Size: 37.8 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 6.3V @ 6 A
  • Secondary VAC RMS Parallel: 3.15V @ 12 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for e
$55.32
Transformer - Hammond, Power, 250-0-250 V, 100 mA
Primary 115 VAC 60 Hz.
Secondary DC current measured with cap. input filter, full wave (two diode) C.T., rectifier circuit.
Enclosed, 4 hole chassis mount.
Minimum 6 long leads.
2" X 2" vertical mounting centers.
Class A insulation (105 degrees C).
Hi-Pot test of 2000 V RMS.
Conservative designs - CSA certified (# LR3902).
3.2lbs
Secondary: 250-0-250 V100 mA
Filament winding 1: 5 V2 A
Filament winding 2: 6.3 V3 A
$92.63
Transformer - Hammond, Guitar Amplifier, replacement for Ampeg
  • Replacement for Ampeg amplifiers
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".



Part No.
Primary
Ampeg Model Names
Ampeg Part No
Bobbin/Paper Wound


VAC
Hz.




P-T291GX
120 V
60 Hz.
B25
12XA
Bobbin


P-T290CAZ
117 V
60 Hz.
Gemini VI 25W
PT 113
Bobbin


P-T290ETX
120 V
60 Hz.
Super Echo Twin
PT 109
Bobbin


P-T291HX
110 / 115 / 230 V
50 / 60 Hz.
V50H
94-270-030
Bobbin
Starting at $105.82
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 120 V
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120-UP for upgraded 120 V transformers, P-T290-FENDER-240 for 240 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Starting at $57.49
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 120 V upgrade
  • Designed for drop in replacement of original units. Upgraded units with variable voltage.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120 for 120 V basic transformers, P-T290-FENDER-240 for 240 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Starting at $118.30
Transformer - Hammond, Guitar Amplifier, replacement for Fender, 240 V
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
  • See P-T290-FENDER-120 for 120 V transformers, P-T290-Fender-120-UP for upgraded 120 V transformers

Warning: Not all amplifier models of the same name use the same transformer model.
Starting at $63.25
Transformer - Hammond, Guitar Amplifier, replacement for Marshall
  • Replacements for Marshall amps
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Starting at $128.95
Transformer - Hammond, Guitar Amplifier, replacement for Vox
  • Replacement for Vox amplifiers
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Starting at $110.80
Transformer - Hammond, Guitar Amplifier, replacement for Yorkville / Traynor
  • Replacement for Yorkville/Traynor amplifiers
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".

Part No. Primary Secondary 1 Secondary 2 Secondary 3 Yorkville / Traynor Amp Yorkville / Traynor Part No VAC Hz. P-T290TRA 120 V 60 Hz. 320 V @ 600 mA 60 V @ 50 mA 6.3 V.C.T. @ 9 A 100 Watt Bass A-1380 P-T290TRB 120 V 60 Hz. 620 V @ 115 mA 6.3 V.C.T. @ 115 mA YBA2-B A-1314 P-T291JX 120 V 60 Hz. 320 V @ 500 mA 60 V @ 20 mA 6.65 V.C.T.
Starting at $107.52
Transformer - Output, 8 W, 4kΩ - 9kΩ impedance
Specifications Output 8 W Primary Impedance 4,000 to 9,000 Ω Mounting Centers 2.375" Weight 0.7 lbs
$21.39
Transformer - Power, 120V primary, 140/28/10.5 V secondary
  • Primary Voltage: 120 V
  • Secondary 1: 140 V @ 100 mA
  • Secondary 2: 28 V @ 20 mA
  • Secondary 3: 10.5 V @ 2 A

Primary voltage = black wires Secondary 1 = Red wires Secondary 2 = Yellow wires Secondary 3 = Green wires
$19.95
Transformer - Hammond, Line Step Up Isolation, Toroidal, 500 VA
Capacity: 500 VA
Dimensions: 9" long by 6" wide by 4" height
Features:
  • Primary 120VAC, 50/60 Hz., Secondary 240VAC.
  • Provides circuit isolation.
  • Toroidal transformer for high isolation, low noise, light weight cool operation and low profile.
  • 50 or 60 Hz.
$379.17
Transformer - Hammond, Line European grounded adaptor plug
Special Order Item
European plug type Used in: Austria; Belgium; Finland; France; Germany; Middle East; Netherlands; Norway; Parts of Africa, Asia ,South America, China, Tahiti and Caribbean; Sweden Features:
  • For use with Hammond transformers
  • Heavy duty design with plastic shell & double wipe contacts.
  • Indoor use only.
  • Allows for ground connection between equipment and international power sources.
  • Adaptors do not affect voltages, they are a mechanical device only to match foreign "pin-outs" of receptacles and/or plugs.
$13.23
Note: special order items require additional lead time. See our page on special order items.
Transformer - Hammond, High Voltage Universal Plate & Filament, Vertical mount
  • Primary: Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz.
    • NOTE: units are designed to operate with BOTH primary windings engaged.
    • See primary wiring information under resources.
  • Bias Tap: 50 VAC tap from high voltage secondary C.T. (except part number P-T379WX - uses a separate 60VAC 0.2 Amp winding).
  • Highpot tested: 2,000 VAC
  • Faraday Copper Primary Shield: Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries (shield is internally grounded to the end bell).
  • Windings: Concentric wound for low stray field and low noise.
  • Models: This series is an upgrade from our P-T263-X range of units PLUS 2 models designed specifically for 300B tubes (Part Number P-T300BX) and 2A3 tubes (Part Number P-T302AX).
  • Finish: Black powder paint to match our P-T1650X series of output transformers Units can be run full wave bridge or full wave C.T.
  • Conservative designs - CSA certified (209651).
Starting at $90.06
Save 9%
Originally: $98.67
Transformer - Hammond, High Voltage Universal Plate & Filament, Horizontal mount
  • Primary: Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz.
    • NOTE: units are designed to operate with BOTH primary windings engaged.
    • See primary wiring information under resources.
  • Bias Tap: 50 VAC tap from high voltage secondary C.T.
Starting at $129.42
Transformer - Output, 8 W, Single Ended
Specifications
  • Power: 8 W
  • Primary Impedance: 5,000 Ω single-ended
  • Secondary Impedance: 8 Ω
  • Primary DC Resistance (Red to Blue): 230 Ω
  • Mounting Centers: 2.375"
  • Mounting Type: U-bracket
  • Weight: 0.7 lbs
$20.85
Transformer - 42TL019, Audio & Signal, 10KΩ:600Ω, PC Mount
Small 42TM018 audio transformers with a 10KΩ:600Ω impedance. This transformer is a popular choice for pickup simulators in various effects such as fuzz pedals. The leads are soft metal wire and can be adjusted to fit a variety of applications. RoHS compliant. Rated for 200mW.
$5.55
Transformer - 42TM022, Audio & Signal, 1.5KΩ:600Ω, PC Mount
Small 42TM022 audio transformers with a 1.5KΩ:600Ω impedance. This transformer is a popular choice for octavia style builds as well as ring modulators. The leads are soft metal wire and can be adjusted to fit a variety of applications. RoHS compliant. Rated for 200mW.
$5.65
Transformer - Audio Interstage, Coil Assembly for P-T156
Coil assembly for P-T156. Use your own iron to preserve mechanical fit. Coil window is 1/2 x ½".
$15.65
Transformer - Power, 117 V primary, 125 V @ 15 mA secondary
Specifications Primary 117 V, 50/60 Hz Secondary 125 V, 15 mA Filament Winding 12.6V, 0.3 A Mounting Centers 2" Mounting Type U-bracket Weight 0.7 lbs
$19.95