Transformers & Chokes

Transformer - Hammond, High Voltage Plate, 115 VAC, 50 / 60 Hz
  • Primary 115 VAC, 50 / 60 Hz.
  • At 2,000 VAC and above, secondary leads are through rubber bushings
  • Units can be run full wave bridge or full wave C.T.
  • V.A. is a C.C.S. rating
  • Current ratings are CCS (Continuous Commercial Service) & ICAS ratings (Intermittent Commercial or Amateur Service).
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Class A insulation (105 degrees C).
  • Hi-Pot test at a minimum of twice secondary voltage
  • Conservative designs - CSA certified (209651).
Starting at $111.00
Transformer - Hammond, Guitar Amplifier, replacement for Vox
  • Replacement for Vox amplifiers
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Starting at $110.80
Transformer - Hammond, Toroidal Power, 12V / 24V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 24 V series, 12 V parallel secondary.
Starting at $63.65
Transformer - Hammond, Low Voltage, Single Primary, 10V 5A
Special Order Item
Secondary VAC: 10V C.T.
Current: 5 A
VA Rating: 50
Features:
  • Single Primary 115VAC
  • Operates on 50/60 Hz.
  • Combination solder or quick connect terminals.
  • Split bobbin construction eliminates the need for an electrostatic shield.
  • Hi-pot tested to 2 KV RMS.
  • Economical open style, channel frame - chassis mount design
  • UL recognized & CSA certified.
$24.15
Note: special order items require additional lead time. See our page on special order items.
Transformer - Hammond, Low Voltage / Filament, Open, 12 V no tap
Special Order Item
Open style, chassis mount transformers with a 117V 50/60Hz primary and a 12V secondary.
Starting at $15.82
Note: special order items require additional lead time. See our page on special order items.
Transformer - Hammond, Power, 250-0-250 V, 100 mA
Primary 115 VAC 60 Hz.
Secondary DC current measured with cap. input filter, full wave (two diode) C.T., rectifier circuit.
Enclosed, 4 hole chassis mount.
Minimum 6 long leads.
2" X 2" vertical mounting centers.
Class A insulation (105 degrees C).
Hi-Pot test of 2000 V RMS.
Conservative designs - CSA certified (# LR3902).
3.2lbs
Secondary: 250-0-250 V100 mA
Filament winding 1: 5 V2 A
Filament winding 2: 6.3 V3 A
$92.63
Transformer - Hammond, Low Voltage / Filament, Open, 120 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 120V center tapped secondary.
$34.25
Power Transformer - Hammond, 115V, 28VCT
Special Order Item
  • Both series operate on 50/60 Hz current
  • Low profile, split bobbin design.
  • Dual winding secondaries, non-concentrically wound
  • Units are designed so that all windings must be used
  • Low primary to secondary coupling - no electrostatic shield required.
  • High insulation - Hipot of 2,500V RMS.
  • Class B insulation - 130 degrees C.
  • c UL us recognized
Starting at $10.70
Note: special order items require additional lead time. See our page on special order items.
Transformer - Hammond, High Voltage Universal Plate & Filament, Vertical mount
  • Primary: Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz.
    • NOTE: units are designed to operate with BOTH primary windings engaged.
    • See primary wiring information under resources.
  • Bias Tap: 50 VAC tap from high voltage secondary C.T. (except part number P-T379WX - uses a separate 60VAC 0.2 Amp winding).
  • Highpot tested: 2,000 VAC
  • Faraday Copper Primary Shield: Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries (shield is internally grounded to the end bell).
  • Windings: Concentric wound for low stray field and low noise.
  • Models: This series is an upgrade from our P-T263-X range of units PLUS 2 models designed specifically for 300B tubes (Part Number P-T300BX) and 2A3 tubes (Part Number P-T302AX).
  • Finish: Black powder paint to match our P-T1650X series of output transformers Units can be run full wave bridge or full wave C.T.
  • Conservative designs - CSA certified (209651).
Starting at $90.06
Save 9%
Originally: $98.67
Transformer - Hammond, Toroidal Power, 18V / 36V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 36 V series, 18 V parallel secondary.
Starting at $57.68
Transformer - Hammond, Low Voltage, Dual Primary, 12.6V 4A
Special Order Item
Secondary VAC: 12.6V C.T.
Current: 4 A
VA Rating: 50.4
Features:
  • Dual Primary 115/230VAC
  • Operates on 50/60 Hz.
  • Combination solder or quick connect terminals.
  • Split bobbin construction eliminates the need for an electrostatic shield.
  • Hi-pot tested to 2 KV RMS.
  • Economical open style, channel frame - chassis mount design
  • UL recognized & CSA certified.
$21.73
Note: special order items require additional lead time. See our page on special order items.
Transformer - Hammond, Low Voltage / Filament, Open, 25 V no tap
Special Order Item
Open style, chassis mount transformers with a 117V 50/60Hz primary and a 25V secondary.
$23.45