Transformers & Chokes

Transformer - Hammond, High Voltage Universal Plate & Filament, Vertical mount
  • Primary: Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz.
    • NOTE: units are designed to operate with BOTH primary windings engaged.
    • See primary wiring information under resources.
  • Bias Tap: 50 VAC tap from high voltage secondary C.T. (except part number P-T379WX - uses a separate 60VAC 0.2 Amp winding).
  • Highpot tested: 2,000 VAC
  • Faraday Copper Primary Shield: Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries (shield is internally grounded to the end bell).
  • Windings: Concentric wound for low stray field and low noise.
  • Models: This series is an upgrade from our P-T263-X range of units PLUS 2 models designed specifically for 300B tubes (Part Number P-T300BX) and 2A3 tubes (Part Number P-T302AX).
  • Finish: Black powder paint to match our P-T1650X series of output transformers Units can be run full wave bridge or full wave C.T.
  • Conservative designs - CSA certified (209651).
Starting at $90.06
Save 9%
Originally: $98.67
Partially Out of Stock
Transformer - Hammond, High Voltage Universal Plate & Filament, Horizontal mount
  • Primary: Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz.
    • NOTE: units are designed to operate with BOTH primary windings engaged.
    • See primary wiring information under resources.
  • Bias Tap: 50 VAC tap from high voltage secondary C.T.
Starting at $129.42
Transformer - Power, 117 V primary, 125 V @ 15 mA secondary
Specifications Primary 117 V, 50/60 Hz Secondary 125 V, 15 mA Filament Winding 12.6V, 0.3 A Mounting Centers 2" Mounting Type U-bracket Weight 0.7 lbs
$19.95
Transformer - Hammond, High Voltage Plate, 115 VAC, 50 / 60 Hz
  • Primary 115 VAC, 50 / 60 Hz.
  • At 2,000 VAC and above, secondary leads are through rubber bushings
  • Units can be run full wave bridge or full wave C.T.
  • V.A. is a C.C.S. rating
  • Current ratings are CCS (Continuous Commercial Service) & ICAS ratings (Intermittent Commercial or Amateur Service).
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Class A insulation (105 degrees C).
  • Hi-Pot test at a minimum of twice secondary voltage
  • Conservative designs - CSA certified (209651).
Starting at $111.00
Transformer - Fender®, Power, Hot Rod Deluxe
Fender Original Hot Rod Deluxe Power Transformer. Equivalent to #036958.



Specifications



Primary
120 VAC @ 60 Hz (Black - White)


Secondary 1 (Red - Red)
495 VDC unloaded, 440 VDC @ 65.7 mA DC, 388 VDC @ 200 mA DC


Secondary 2 (Brown - Brown)
53.6 VAC @ 1.58 A AC


Secondary 3 (Green - Green)
6.6 VAC @ 3.75 A AC


Warning: Not all amplifier models of the same name use the same transformer model. Please make sure the amplifier transformer which you are replacing has a Fender number matching the equivalent Fender transformer number listed here.
$145.95
Transformer - Fender, Power, for Deluxe Reverb 120V
Genuine Fender power transformer designed for use in the ‘65 Deluxe Reverb as well as the ‘68 Deluxe. Made to original fender specifications. 120V Primary
$105.95
Transformer - Fender®, Power, Hot Rod Deville
Fender Original Hot Rod DeVille Power Transformer. Equivalent to #041752.
$99.95
Transformer - Fender®, Power, Blues Junior, 15 W
Fender Original Blues Junior Power Transformer. Equivalent to #049967.
$87.95
Transformer - Power, 120V Primary, 325/275V / 6.3VCT / 5V Secondary, for Fender® Champ
Power transformer replacement for the Fender® part numbers 125P1B, 022772, and 66079B. This transformer offers two different B+ options for lower voltage or higher voltage builds. This transformer is used in versions of the:
  • Bronco
  • Champ
  • Princeton
  • Princeton Reverb
  • Vibro Champ

Features
  • 275V or 325V (650/550 VCT) B+ options at 100mA
  • Center tapped 6.3V filament at 2.25A
  • 5V filament supply at 3A
  • For 120V 60Hz primary
  • Standard 2.5” x 2” mounting centers
$59.95
Transformer - Power, 120V Primary, 330V / 6.3VCT / 5V Secondary, for Fender® Deluxe 5E3
Power transformer replacement for the Fender® part number 64526 as used in the 5E3 Deluxe Amp. This transformer accounts for modern mains voltage and will provide a B+ voltage of ~370VDC with 120VAC on the primary in a standard 5E3 build paired with the P-TGO-002 output transformer. This upgraded transformer also features a center tap on the 6.3V filament. Features
  • Provides vintage correct DC voltages in stock 5E3 builds
  • 330V (660 VCT) B+ at 120mA
  • Center tapped 6.3V filament at 2A
  • 5V filament supply at 2A
  • For 120V 60Hz primary
  • Standard 2.8125" x 2.25” mounting centers
$89.95
Transformer - Marshall, Power, 50 W, for JCM 900
Special Order Item
Genuine Marshall™ 50 watt power transformer for JCM900.
$115.00
Out of Stock
Transformer - Isolation, 35 VA, 115V, 300 mA, 1 x 115V
35VA chassis mount Power Transformer for isolating equipment from direct connection to the power line. It is constructed with non-concentrically wound coils. The primary and secondary are wound on separate arbors, then assembled on a laminate core side-by-side separated by insulation. This prevents electrical connection under normal or overload conditions between the primary and secondary windings. These units are designed with 1500V isolation between winding to winding and between winding and core. Materials and construction are rated for Class B insulation system.
$24.95
Transformer - Isolation, 50 VA, 115V, 435 mA, 2 x 115V
An Isolation Power Transformer for isolating equipment from direct connection to the power line. The transformer is constructed with non-concentrically wound coils. The primary and secondary are wound on separate arbors, then assembled on a laminate core side-by-side separated by insulation. This prevents electrical connection, under normal or overload conditions, between the primary and secondary windings.
$23.49