You are here

Transformers & Chokes

Filter these results
Sort By:
products per page
View Mode: List View · Grid View

Pages

(19 pages)
Transformer - Hammond, Power, Low voltage, 6.3V/6A

Specifications:



  • Size: 37.8 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 6.3V @ 6 A
  • Secondary VAC RMS Parallel: 3.15V @ 12 A


Features:



  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for e

$39.38
Click to read more
Transformer - Hammond, Line Step Up Isolation, Toroidal, 500 VA
Capacity: 500 VA
Dimensions: 9" long by 6" wide by 4" height
Features:
  • Primary 120VAC, 50/60 Hz., Secondary 240VAC.
  • Provides circuit isolation.
  • Toroidal transformer for high isolation, low noise, light weight cool operation and low profile.
  • 50 or 60 Hz.
$270.24
Click to read more
P-T298G4Transformer - Hammond, Line European grounded adaptor plug

Special Order Item

Europeon plug type Used in: Austria; Belgium; Finland; France; Germany; Middle East; Netherlands; Norway; Parts of Africa, Asia ,South America, China, Tahiti and Caribbean; Sweden Features:



  • For use with Hammond transformers
  • Heavy duty design with plastic shell & double wipe contacts.
  • Indoor use only.
  • Allows for ground connection between equipment and international power sources.
  • Adaptors do not affect voltages, they are a mechanical device only to match foreign "pin-outs" of receptacles and/or plugs.

$8.57
Note: special order items require additional lead time. See our page on special order items.
Note: this is a special order item.
Click to read more
Transformer - Hammond, High Voltage Universal Plate & Filament, Horizontal mount
  • Primary: Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz.
    • NOTE: units are designed to operate with BOTH primary windings engaged.
    • See primary wiring information under resources.
  • Bias Tap: 50 VAC tap from high voltage secondary C.T.

Starting at $111.62
Click to read more
Transformer - Hammond, High Voltage Plate, 115 VAC, 50 / 60 Hz
  • Primary 115 VAC, 50 / 60 Hz.
  • At 2,000 VAC and above, secondary leads are through rubber bushings
  • Units can be run full wave bridge or full wave C.T.
  • V.A. is a C.C.S. rating
  • Current ratings are CCS (Continuous Commercial Service) & ICAS ratings (Intermittent Commercial or Amateur Service).
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Class A insulation (105 degrees C).
  • Hi-Pot test at a minimum of twice secondary voltage
  • Conservative designs - CSA certified (209651).

Starting at $78.99
Click to read more
P-RC-3Choke - One Electron, Audio, PRC-3, 225H for Preamp Output

The PRC-3 audio choke from One Electron was designed as a plate load for the output of either a high quality line amplifier or a phono preamp.


$69.95
Click to read more
P-C1536XChoke - 0.17 - 250, Heavy Duty Hash Choke
Molded powdered iron core.
1-1/4 long axial leads.
High inductance & high current.
L measured at 1 Khz. Inductance: 250 µH20% tolerance
DC resistance ohms: .17
Self Resonant Frequency (MHz): 1.5
Maximum DC current amps: 2.5
Coil diameter (in): .43
Core Length (in): 1.25
$1.08
Click to read more
P-T118944Transformer - Hammond, Radiola III-A Replacement Audio

Developed in response to requests from RCA Radiola III-A collectors. The original transformers are usually found with open" windings due to the fine wire and high turns usedcoupled with age. This is a universal replacement type - it will replace any of the three audio transformers used (1st audio driver2nd audio-phase splitter stage or output transformer)by correctly connectiong the 5 lugs. A pin out and connection diagram is included. The cases from the old transformer will fit this new unit. The terminal board is a duplicate of the original.



Key Features



  • Primary: 4000 turns, #41 wire (lugs 4 & 2)
  • Secondary: 12000 turns C.T., #41 wire (lugs 5 & 1lug 3 is C.T. connection)
  • Termination: Solder lugs on a 1 3/4" x 1" terminal board with 4-5" connecting leads
  • Size: 1-7/8" long x 1-11/16" wide x 1-3/8" deep
  • Lamination Core Size: 5/8" x 1/2"
  • Weight: 7 oz.

$48.25
Click to read more
P-T119DATransformer - Hammond, Audio Interstage, 12 Watt

Developed in response to requests from the Collins Collectors Association"this is a matching audio transformer for older equipment with 600 ohm audio outputdriving modern speakers. Or for "classic" high impedance speakers used with newer equipmentsimply swap primary for secondary (ie...4 or 8 ohm input and 600 ohms out). Key Features Isolation unit: (i.e.


$30.16
Click to read more
P-T125HTransformer - Hammond, Output, 8 W, 10k Primary

Specifications Audio Watts: 8 watts Primary Impendance (Ohms): 10K center-tapped Secondary Impendance (Ohms): 2/4/8 Mounting centers: 2-3/8u-bracket Weight: 1.0 lbs. Cat. No. Dimensions (Inches) A B C D G Mtg. Hole 125H 2.81 1.4 1.7 2.36 0.187


$37.00
Click to read more

Pages

(19 pages)
Don't see a product you're looking for? Send us your product suggestions!
Subscribe to RSS - Transformers & Chokes