P-T167X-12D6Transformer - Hammond, Low Voltage / Filament, Enclosed, 12.6 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 12 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).

Starting at $29.73
Click to read more
Transformer - Hammond, Low Voltage / Filament, Enclosed, 5 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 5 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).

Starting at $29.00
Click to read more
Transformer - Hammond, Low Voltage / Filament, Enclosed, 10 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 10 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).

$47.89
Click to read more
P-T169XSTransformer - Hammond, Line Isolation
  • Primary 115VAC, 60 Hz.
  • Secondary 115VAC
  • Electrostatic shield between primary & secondary
  • Connection by flexible leads, 8" minimum length
  • Perfect for circuit isolation or "Classic" bias power supply
  • CSA certified (209651)
  • Remember - These units do NOT convert line frequency

Starting at $57.87
Click to read more
Transformer - Hammond, line isolation / plug & receptacle
  • Primary 115VAC, 50 / 60 Hz., Secondary 115VAC
  • Provides complete circuit isolation.
  • Electrostatic shield between primary & secondary to greatly attenuate surges and noise.
  • Hi-pot tested to 2 KV RMS.
  • Circuit breaker in primary.
  • Standard 3-wire, grounded plug & receptacle.
  • Input (primary) connected to 5 foot long cord & standard North American plug (NEMA 5-15P).
  • Output (secondary) connected to 1 foot long "pig tail" cord, 3-wire, standard North American grounded receptacle (NEMA 5-15R).
  • North American Mark of Safety - C UL & UL listed (File #E211544)
  • Indoor use only
  • Remember - These units do NOT convert line frequency

$83.26
Starting at $83.26
You save: 0%
Click to read more
P-T266M5Transformer - Hammond, Power, Low V Primary / Secondary, 5V/3A

Specifications:



  • Size: 15 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 5V @ 3 A
  • Secondary VAC RMS Parallel: 2.5V @ 6 A


Features:



  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra p

$35.80
Click to read more
P-T263-ZTransformer - Hammond, High Voltage Plate & Filament, Horizontal mount
  • Horizontal mount. For Vertical Mount, see P-T263-X
  • Primary 117 VAC, 50/60 Hz. - except as noted
  • Enclosed, 4 hole, chassis mount.
  • Minimum 6" long leads.
  • Units can be run full wave bridge or full wave C.T.
  • Class A insulation (105 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • Conservative designs - CSA certified (209651).
  • For Vertical Mount, see P-T263-X

Starting at $65.03
Click to read more
Transformer - Hammond, Toroidal Power, Chassis Mount, 30VA

Specifications



  • VA: 30
  • VAC Secondary (RMS) Series: 12V C.T. @ 2.5A
  • VAC Secondary (RMS) Parallel: 6V @ 5A


Features:



  • Dual Secondary
  • Open Toroid Center
  • Low profile, lightweight, cool running - due to high efficiency toroidal design
  • Dual 117/234 VAC primary, 50/60 Hz.

$68.17
Click to read more
Transformer - Hammond, Low Voltage / Filament, Enclosed, 60 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 60 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).

$65.90
Click to read more
Audio Transformer - Hammond, 150/600Ω, Line Isolation
  • 150/600 Ohm Primary Impedance
  • 300/1200 Ohm Secondary Impedance
  • Deep-drawn steel case with tin plated finish, with two convenient 6-32 mounting studs with mounting hardware.
  • Sealed case and wax potted core internally for stable characteristics and long life.
  • Wide frequency response ± 0.5 db max. from 20 Hz. to 20 Khz. (except units over 5K ohms impedance, may be down 1 db @ 20 Khz.)
  • Insertion loss of apx. 1 db.
  • Maximum power level +15 dbm. with specified characteristics, or higher levels with reduced low frequency performance.
  • Distortion is apx. 1.5% @ 20 Hz. under full power.
  • Electrostatic shield between pri. & sec. connected to the green lead.
  • Humbucking construction
  • Balanced split windings on pri. & sec. for circuit versatility. Primary may be used as a secondary and vice versa for impedance matching.
  • Lead length: Min. 4"

$146.22
Click to read more

Pages

(15 pages)
Don't see a product you're looking for? Send us your product suggestions!
Subscribe to RSS - Transformers & Chokes