Transformers & Chokes

Transformer - Hammond, Low Voltage / Filament, Enclosed, 6.3 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 6.3 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $40.90
Transformer - Hammond, Toroidal Power, 12V / 24V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 24 V series, 12 V parallel secondary.
Starting at $52.49
Transformer - Hammond, Guitar Amplifier, replacement for Vox
  • Replacement for Vox amplifiers
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs. were kept as close as possible to the original part to preserve the stock "tone".
Starting at $102.45
Transformer - Hammond, Power, Low voltage, 48V/1A
Specifications:
  • Size: 48 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 48V @ 1 A
  • Secondary VAC RMS Parallel: 24V @ 2 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for extra p
$37.65
Transformer - Hammond, Low Voltage / Filament, Open, 12 V no tap
Special Order Item
Open style, chassis mount transformers with a 117V 50/60Hz primary and a 12V secondary.
Starting at $14.35
Note: special order items require additional lead time. See our page on special order items.
Transformer - Hammond, Tube Output, Push-Pull
  • Designed for push-pull tube output circuits.
  • Enclosed (shielded), 4 slot, above chassis Type 'X' mounting.
  • Frequency response 30 Hz. to 30 Khz. at full rated power (± 1 db max. - ref.
Starting at $108.67
Transformer - Hammond, Low Voltage / Filament, Open, 18 VCT
  • Open style, chassis mount transformers with a 115V 60Hz or 50/60Hz primary and an 18V center tapped secondary.
Starting at $11.13
Note:
P-T166B18:0.54
P-T166E18:5.4
P-T166J18:18
P-T166K18:27
are special order items.
Note: some of these items are special order items.
Transformer - Hammond, Low Voltage / Filament, Open, 120 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 120V center tapped secondary.
$31.06
Transformer - Marshall, Output, 100 W, for JCM900
Genuine Marshall™ 100 watt output transformer for JCM900 and JCM2000.
$139.95
Transformer - Hammond, Low Voltage / Filament, Open, 30 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 30 C.T.
  • Center tapped secondary.
  • Open style, channel bracket, two hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C).
  • Hi-Pot test of 2,000 V RMS.
  • UL listed (# E50394) & CSA certified (# LR3902).
Starting at $23.90
Note: P-T166E30: 4.5 is a special order item.
Transformer - Hammond, Isolation / plug & receptacle
  • Primary 115VAC, 50 / 60 Hz., Secondary 115VAC
  • Provides complete circuit isolation.
  • Electrostatic shield between primary & secondary to greatly attenuate surges and noise.
  • Hi-pot tested to 2 KV RMS.
  • Circuit breaker in primary.
  • Standard 3-wire, grounded plug & receptacle.
  • Input (primary) connected to 5 foot long cord & standard North American plug (NEMA 5-15P).
  • Output (secondary) connected to 1 foot long "pig tail" cord, 3-wire, standard North American grounded receptacle (NEMA 5-15R).
  • North American Mark of Safety - C UL & UL listed (File #E211544)
  • Indoor use only
  • Remember - These units do NOT convert line frequency
Starting at $113.60
Transformer - Hammond, Toroidal Power, 18V / 36V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 36 V series, 18 V parallel secondary.
Starting at $52.32
Transformer - Power, 120V primary, 140/28/10.5 V secondary
  • Primary Voltage: 120 V
  • Secondary 1: 140 V @ 100 mA
  • Secondary 2: 28 V @ 20 mA
  • Secondary 3: 10.5 V @ 2 A

Primary voltage = black wires Secondary 1 = Red wires Secondary 2 = Yellow wires Secondary 3 = Green wires
$19.95
Transformer - Hammond, Power, Low voltage, 12.6V/4A
Specifications:
  • Size: 50.4 VA
  • Dual Primary: 117 VAC, 234VAC, 50/60 Hz.
  • Secondary VAC RMS Series: 12.6V @ 4 A
  • Secondary VAC RMS Parallel: 6.3V @ 8 A

Features:
  • Primary 117/234 VAC, 50/60 Hz.
  • Dual secondaries
  • Secondaries can be used as; a center tapped secondary, parallel connected or used individually
  • Units are designed for use with all windings engaged.
  • Open style.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees, C) for ex
$42.65
Transformer - Hammond, Low Voltage / Filament, Open, 25 V no tap
Special Order Item
Open style, chassis mount transformers with a 117V 50/60Hz primary and a 25V secondary.
$21.27
Note: special order items require additional lead time. See our page on special order items.
Transformer - Hammond, Output, Single-Ended, 30 W
  • Over designed for single ended tube output circuits (triode, tetrode or pentode tubes).
  • Enclosed (shielded), 4 slot, above chassis Type 'X' mounting.
  • Frequency response at least 20 Hz. to 20 Khz. at full rated power (± 1 db max. ref.
Starting at $202.95
Transformer - Hammond, Low Voltage / Filament, Enclosed, 25 VCT
  • Primary 115 VAC, 60 Hz.
  • Secondary 25 C.T.
  • All secondaries center tapped, VAC (RMS)
  • Enclosed, 4 hole chassis mount.
  • Minimum 6" long leads.
  • Dual bobbin design - no electrostatic shield required.
  • Class B insulation (130 degrees C).
  • Hi-Pot test of 2,000V RMS.
  • UL listed (# E50394) & CSA certified (209651).
Starting at $39.08
Transformer - Hammond, Low Voltage / Filament, Open, 35 VCT
Open style, chassis mount transformers with a 115V 60Hz primary and a 35V center tapped secondary.
$40.63
Transformer - Marshall, Power, 50 W, for JCM 900
Special Order Item
Genuine Marshall™ 50 watt power transformer for JCM900.
$115.00
Out of Stock
Transformer - Isolation, 50 VA, 115V, 435 mA, 2 x 115V
An Isolation Power Transformer for isolating equipment from direct connection to the power line. The transformer is constructed with non-concentrically wound coils. The primary and secondary are wound on separate arbors, then assembled on a laminate core side-by-side separated by insulation. This prevents electrical connection, under normal or overload conditions, between the primary and secondary windings.
$20.95
Transformer - Hammond, Power, 250-0-250 V, 100 mA
Primary 115 VAC 60 Hz.
Secondary DC current measured with cap. input filter, full wave (two diode) C.T., rectifier circuit.
Enclosed, 4 hole chassis mount.
Minimum 6 long leads.
2" X 2" vertical mounting centers.
Class A insulation (105 degrees C).
Hi-Pot test of 2000 V RMS.
Conservative designs - CSA certified (# LR3902).
3.2lbs
Secondary: 250-0-250 V100 mA
Filament winding 1: 5 V2 A
Filament winding 2: 6.3 V3 A
$68.72
Transformer - Hammond, Toroidal Power, 24V / 48V secondary
Dual 117/234 VAC primary, 50/60 Hz. operation. 48 V series, 24 V parallel secondary.
Starting at $127.94
Transformer - Hammond, High Voltage Universal Plate & Filament, Vertical mount
  • Primary: Universal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz.
    • NOTE: units are designed to operate with BOTH primary windings engaged.
    • See primary wiring information under resources.
  • Bias Tap: 50 VAC tap from high voltage secondary C.T. (except part number P-T379WX - uses a separate 60VAC 0.2 Amp winding).
  • Highpot tested: 2,000 VAC
  • Faraday Copper Primary Shield: Our electrostatic shield reduces the capacitive coupling from the primary - greatly attenuating higher frequency current coupling to the secondaries (shield is internally grounded to the end bell).
  • Windings: Concentric wound for low stray field and low noise.
  • Models: This series is an upgrade from our P-T263-X range of units PLUS 2 models designed specifically for 300B tubes (Part Number P-T300BX) and 2A3 tubes (Part Number P-T302AX).
  • Finish: Black powder paint to match our P-T1650X series of output transformers Units can be run full wave bridge or full wave C.T.
  • Conservative designs - CSA certified (209651).
Starting at $89.49
Transformer - Hammond, Line Step Up Isolation, Toroidal, 500 VA
Capacity: 500 VA
Dimensions: 9" long by 6" wide by 4" height
Features:
  • Primary 120VAC, 50/60 Hz., Secondary 240VAC.
  • Provides circuit isolation.
  • Toroidal transformer for high isolation, low noise, light weight cool operation and low profile.
  • 50 or 60 Hz.
$343.92