P-T291DXTransformer - Hammond, 120V upgrade for Super/Pro Reverb, etc.
Replacement for Fender Super Reverb, Pro Reverb, Bandmaster Reverb, Tweed Bassman
Equivalent to Fender part number 125P5D & 022798
Primary:120 VAC, 60 Hz.
For 120V drop-in version, see P-T290DX
For 240V drop-in version, see P-T290DEX
For 240V upgrade version, see P-T291DEX
Features:
  • Designed for drop in replacement of original units.
  • Physically, parts were designed to look similar to original factory units (where possible).
  • Material used & design specs.
$150.97
$132.85
You save: 12%
Special Order Item
Please Contact us or call us at 480.820.5411 to order this item.
Click to read more
P-T369GXTransformer - Hammond, Power, 225-0-225 V, 75 mA
  • Universal Primary - 100, 110, 120, 200, 220, 240 VAC 50/60 Hz.
  • High voltage secondary designed for full wave center tapped use.
  • 50 VAC bias tap from high voltage secondary C.T.
  • Black epoxy painted to match our P-T1650 series of output transformers.
  • Class A insulation (105 degrees C).
  • Hi-Pot test of 2,000 V RMS.
  • Windings are concentric wound for low stray field and low noise.
Secondary: 225-0-225 V, 75 mA
Filament winding 1 : 6.3 VCT, 2.5 A
Mounting centers: 2" x 1.69" vertical mount
Weight: 2.4 lbs.
$86.71
$76.30
You save: 12%
Special Order Item
Please Contact us or call us at 480.820.5411 to order this item.
Click to read more
P-T369JXTransformer - Hammond, Power, 250-0-250 V, 69 mA
  • Universal Primary - 100, 110, 120, 200, 220, 240 VAC 50/60 Hz.
  • High voltage secondary designed for full wave center tapped use.
  • 50 VAC bias tap from high voltage secondary C.T.
  • Black epoxy painted to match our P-T1650 series of output transformers.
  • Class A insulation (105 degrees C).
  • Hi-Pot test of 2,000 V RMS.
  • Windings are concentric wound for low stray field and low noise.
Secondary: 250-0-250 V, 69 mA
Filament winding 1 : 6.3 VCT, 2.5 A
Mounting centers: 2" x 1.69" vertical mount
Weight: 2.5 lbs.
$88.87
$78.21
You save: 12%
Special Order Item
Please Contact us or call us at 480.820.5411 to order this item.
Click to read more
P-T370DAXTransformer - Hammond, Power, 260-0-260 V, 104 mA, Univ. Primary
  • Universal Primary - 100, 110, 120, 200, 220, 240 VAC 50/60 Hz.
  • High voltage secondary designed for full wave center tapped use.
  • 50 VAC bias tap from high voltage secondary C.T.
  • Black epoxy painted to match our P-T1650 series of output transformers .
  • Class A insulation (105 degrees C).
  • Hi-Pot tested to 2,500 VAC.
  • Windings are concentric wound for low stray field and low noise.


Secondary: 260-0-260 V, 104 mA Filament winding 1 : 5 VCT, 3 A Filament winding 2 : 6.3 VCT, 5 A Mounting centers: 2.5" x 2.94" vertical mount Weight


$105.35
$92.71
You save: 12%
Special Order Item
Please Contact us or call us at 480.820.5411 to order this item.
Click to read more
P-T370EXTransformer - Hammond, Power, 275-0-275 V, 144 mA, Univ. Primary
  • Universal Primary - 100, 110, 120, 200, 220, 240 VAC 50/60 Hz.
  • High voltage secondary designed for full wave center tapped use.
  • 50 VAC bias tap from high voltage secondary C.T.
  • Black epoxy painted to match our P-T1650 series of output transformers .
  • Class A insulation (105 degrees C).
  • Hi-Pot tested to 2,500 VAC.
  • Windings are concentric wound for low stray field and low noise.


Secondary: 275-0-275 V, 144 mA Filament winding 1 : 5 VCT, 3 A Filament winding 2 : 6.3 VCT, 4 A Mounting centers: 2.5" x 2.44" vertical mount Weight


$120.21
$105.78
You save: 12%
Special Order Item
Please Contact us or call us at 480.820.5411 to order this item.
Click to read more
P-T370JXTransformer - Hammond, Power, 250-0-250 V, 161 mA
  • Universal Primary - 100, 110, 120, 200, 220, 240 VAC 50/60 Hz.
  • High voltage secondary designed for full wave center tapped use.
  • 50 VAC bias tap from high voltage secondary C.T.
  • Black epoxy painted to match our P-T1650 series of output transformers .
  • Class A insulation (105 degrees C).
  • Hi-Pot tested to 2,500 VAC.
  • Windings are concentric wound for low stray field and low noise.
Secondary: 250-0-250 V, 161 mA
Filament winding 1 : 5 VCT, 3 A
Filament winding 2 : 6.3 VCT, 6 A
Mounting centers: 2.5" x 2.94" vertical mount
Weight
$161.32
$141.96
You save: 12%
Special Order Item
Please Contact us or call us at 480.820.5411 to order this item.
Click to read more
P-T373AZTransformer - Hammond, Power, 325-0-325 V, 46 mA, Univ. Primary
  • Universal Primary - 100, 110, 120, 200, 220, 240 VAC 50/60 Hz.
  • High voltage secondary designed for full wave center tapped use.
  • 50 VAC bias tap from high voltage secondary C.T.
  • Black epoxy painted to match our P-T1650 series of output transformers .
  • Class A insulation (105 degrees C).
  • Hi-Pot tested to 2,500 VAC.
  • Windings are concentric wound for low stray field and low noise.


Secondary: 325-0-325 V, 46 mA Filament winding 1 : 5 VCT, 2 A Filament winding 2 : 6.3 VCT, 2 A Mounting centers: horizontal mount Weight: 2.5 lbs.


$118.86
$104.60
You save: 12%
Special Order Item
Please Contact us or call us at 480.820.5411 to order this item.
Click to read more
P-T373EXTransformer - Hammond, Power, 325-0-325 V, 345 mA
  • Universal Primary - 100, 110, 120, 200, 220, 240 VAC 50/60 Hz.
  • High voltage secondary designed for full wave center tapped use.
  • 50 VAC bias tap from high voltage secondary C.T.
  • Black epoxy painted to match our P-T1650 series of output transformers .
  • Class A insulation (105 degrees C).
  • Hi-Pot tested to 2,500 VAC.
  • Windings are concentric wound for low stray field and low noise.
Secondary: 325-0-325 V, 345 mA
Filament winding 1 : 5 VCT, 6 A
Filament winding 2 : 6.3 VCT, 9 A
Mounting centers: 3.5" x 3.25" vertical mount
Weight
$228.12
$200.75
You save: 12%
Special Order Item
Please Contact us or call us at 480.820.5411 to order this item.
Click to read more
P-T373HXTransformer - Hammond, Power, 350-0-350 V, 403 mA
  • Universal Primary - 100, 110, 120, 200, 220, 240 VAC 50/60 Hz.
  • High voltage secondary designed for full wave center tapped use.
  • 50 VAC bias tap from high voltage secondary C.T.
  • Black epoxy painted to match our P-T1650 series of output transformers .
  • Class A insulation (105 degrees C).
  • Hi-Pot tested to 2,500 VAC.
  • Windings are concentric wound for low stray field and low noise.
Secondary: 350-0-350 V, 403 mA
Filament winding 1 : 5 VCT, 6 A
Filament winding 2 : 6.3 VCT, 9 A
Mounting centers: 3.5" x 4" vertical mount
Weight: 1
$254.74
$224.17
You save: 12%
Special Order Item
Please Contact us or call us at 480.820.5411 to order this item.
Click to read more
P-T376XTransformer - Hammond, Power, 320-0-320 V, 173 mA
  • Universal Primary - 100, 110, 120, 200, 220, 240 VAC 50/60 Hz.
  • High voltage secondary designed for full wave center tapped use.
  • 50 VAC bias tap from high voltage secondary C.T.
  • Black epoxy painted to match our P-T1650 series of output transformers .
  • Class A insulation (105 degrees C).
  • Hi-Pot tested to 2,500 VAC.
  • Windings are concentric wound for low stray field and low noise.
Secondary: 320-0-320 V, 173 mA
Filament winding 1 : 5 VCT, 3 A
Filament winding 2 : 6.3 VCT, 5 A
Mounting centers: 2.5" x 2.69" vertical mount
Weight
$178.28
$156.89
You save: 12%
Special Order Item
Please Contact us or call us at 480.820.5411 to order this item.
Click to read more