Carr-Nagy Corp. 100-62
Model: | 100-62 |
Manufacturer: | Carr-Nagy Corp. |
Schematics Content
Page 1:
CARR - NAGY CORP.
MODEL 100-62
Page 2:
MODEL 100-62
CARR - NAGY CORP.
BAND- SWITCH SHOWN
AT 1ST POSITION. SHORT WAVE BAND
5.2 -19 MC.
BAND - SWITCH SHOWN
AT 2ND POSITION. BROADCAST BAND
550-1750 KC.
Page 3:
CARR - NAGY CORP.
HODEL 100.62
NOTE
1 - IDLER PULLEYS
2 - TUNING COND. SHAFT
TWO COMPLETE TURNS ON TUNING SHAFT
ALIGNMENT PROCEDURE, Volume control full on.
I-F ADJUSTMENT: Set Signal Generator at 456 kc. and connect it through a 0.1 - mf condenser to pin No. 4 of 2nd i-f tube, 12SK7. Peak for maximum response.
Connect generator lead to pin No.4 of 1st i-f tube, 12SK7 and peak first i-f transformer for maximum response. Repeat above procedure.
OSCILLATOR TRACKING ADJUSTMENT: Set Signal Generator to 600 kc and connect it to independent loop antenna. Place this loop near loop in receiver. Set dial pointer to 600 kc on scale. Adjust C-2 for maximum response, while rocking gang condenser each side of frequency.
R-F ALIGNMENT: Set signal generator to 1600 kc. Set dial pointer to 1600 kc on scale. Adjust C-1 for maximum response.
Disconnect generator lead from loop and connect to Short-Wave Antenna coil primary. Set frequency of generator to 18 mc. Set dial pointer to 18 mc on SW scale. Turn Band Switch to "SW" position. Adjust C-5 for maximum response.