Carr-Nagy Corp. 100-62 Schematic

Carr-Nagy Corp. 100-62

Get a print!

$8.00
Product Information:
Model:100-62
Manufacturer:Carr-Nagy Corp.

Schematics Content

Page 1:

CARR - NAGY CORP.

MODEL 100-62

Page 2:

MODEL 100-62

CARR - NAGY CORP.

BAND- SWITCH SHOWN
AT 1ST POSITION. SHORT WAVE BAND
5.2 -19 MC.

BAND - SWITCH SHOWN
AT 2ND POSITION. BROADCAST BAND
550-1750 KC.

Page 3:

CARR - NAGY CORP.

HODEL 100.62

NOTE
1 - IDLER PULLEYS
2 - TUNING COND. SHAFT

TWO COMPLETE TURNS ON TUNING SHAFT

ALIGNMENT PROCEDURE, Volume control full on.
I-F ADJUSTMENT: Set Signal Generator at 456 kc. and connect it through a 0.1 - mf condenser to pin No. 4 of 2nd i-f tube, 12SK7. Peak for maximum response.
Connect generator lead to pin No.4 of 1st i-f tube, 12SK7 and peak first i-f transformer for maximum response. Repeat above procedure.

OSCILLATOR TRACKING ADJUSTMENT: Set Signal Generator to 600 kc and connect it to independent loop antenna. Place this loop near loop in receiver. Set dial pointer to 600 kc on scale. Adjust C-2 for maximum response, while rocking gang condenser each side of frequency.

R-F ALIGNMENT: Set signal generator to 1600 kc. Set dial pointer to 1600 kc on scale. Adjust C-1 for maximum response.
Disconnect generator lead from loop and connect to Short-Wave Antenna coil primary. Set frequency of generator to 18 mc. Set dial pointer to 18 mc on SW scale. Turn Band Switch to "SW" position. Adjust C-5 for maximum response.