Monitor Equipment Corp. TA56M Schematic

Monitor Equipment Corp. TA56M

Get a print!

$8.00
Product Information:
Model:TA56M
Manufacturer:Monitor Equipment Corp.

Schematic Pages

PNG: Page 1 Rider Manual Volume 16
PNG: Page 2 Rider Manual Volume 16

Schematics Content

Page 1:

SCHEMATIC DIAGRAM
When using direct current it may be necessary to reverse the position of the power plug in the electric outlet for correct polarity. Reversing the position of the power plug when alternating current is used may reduce power hum. UNDER NO CIRCUMSTANCES SHOULD A GROUND BE CONNECTED TO THIS RECEIVER.

PARTS LIST
Figures in first column correspond to figures in Schematic Diagram

Page 2:

DESCRIPTION

TYPE: Five-tube, single-band, superheterodyne.
FREQUENCY RANGE: 540 to 1600 kc.
INTERMEDIATE FREQUENCY: 455 kc.
POWER SUPPLY: a.C.-d.c.
VOLTAGE RATING: 105-125 volts.
POWER CONSUMPTION: 35 watts nominal.
POWER OUTPUT: 1 watt minimum.
DIAL BULB: Type 47, 6.3 volts,. 15 amp.

ALIGNMENT PROCEDURE
1. Turn the tuning condenser to the completely closed position against the stop and set the dial pointer to the reference line at the end of the dial scale.
2. Connect the output meter across the speaker voice coil.,
3. The r.f. signal input from the signal generator should be connected to the external antenna lead. Connect the signal generator ground through a 0.1 mfd. condenser to - B (pin 4 on 14A7 tube socket).
4. Turn the volume control on full and adjust the signal generator output to produce approximately mid-scale deflection of the out put meter, but maintain signal generator output as low as possible to prevent AVC action in the receiver.

ALIGNMENT CHART
Alignment adjustment locations are shown in Chassis, Side View at the right.