Rauland Corp. 546T Schematic

Rauland Corp. 546T

Get a print!

$8.00
Product Information:
Model:546T
Manufacturer:Rauland Corp.

Schematic Pages

PNG: Page 1 Rider Manual Volume 15

Schematics Content

Page 1:

1 F = 455 KC

FREQ. RANGE 535 K.C. TO 1620 K.C.
VOLTAGES CHECKED TO COMMON - WITH 1000 OHM PER VOLT METER ON 250 VOLT RANGE EXCEPT AS NOTED
ALL RESISTORS 1/2 WATT 20 %
UNLESS OTHERWISE SPECIFIED

I.F. ALIGNMENT - Set the gang condenser to minimum capacity. Connect the hot side of the signal generator to stator
lug of large condenser section through a.05 mf. condenser, and connect the ground lead of the generator to receiver
B minus common. Adjust the four I.F. trimmers for maximum response at 455 kc.

R.F. ALIGNMENT - Set dial pointer at 160. Feed 1600 kc. from the signal generator into a loop of wire approximately
one foot in diameter, located about one foot from the receiver loop. Adjust the oscillator trimmer for maximum response.
Set the dial to 140 and adjust the r.f. trimmer for maximum response at 1400 kc.