Symphony Radio & Telev. Corp. 200
Model: | 200 |
Manufacturer: | Symphony Radio & Telev. Corp. |
Schematic Pages
Schematics Content
Page 1:
ALIGNMENT INSTRUCTIONS
Keep the gain of the signal generator as low as possible on all alignment work.
IMPORTANT. The volume control must be set at max gain on all alignment work.
1. Turn variable condenser fully closed.
2. Connect signal generator through A .1-MFD Cond. and connect to the grid of the 12BE6 tube.
3. Align IF's to 455 K.C. max. reading
RF CALIBRATION
1. Turn variable condenser fully open
2. Place signal generator leads near loop antenna
3. Set signal generator to 1720 K.C.
4. Align osc. section B of variable condenser for max reading
5. Set signal generator to 1500 K.C.
6. Turn variable condenser to 150 on dial and align RF C section of var. cond. for max. reading
NOTE FOR MODEL # 200 ONLY 117 VOLTS AC. 60-50 CYCLES
FOR MODEL # 200 L - R 117 VOLTS ACDC.